Skip to main content
Skip to main content
Product title:

Harman Direct Vent Wall Pass Through Thimble with OAK- 3" & 4" Pellet Vent Pipe: 1-00-677177

Product rating:
Product price:
$349.99
Product SKU ! 1-00-677177
Product MPN ! 1-00-677177
Bullet point features

Frequently Bought Together

Total Price: $444.97

Description

This direct vent wall pass-through thimble is made by Harman and is listed as a compatible venting component for Harman pellet stoves and inserts when using Simpson Pellet Vent Pro pellet venting.

Venting and 3" OAK hose sold separately.

  • The exhaust opening will accommodate both 3" and 4" vent diameters and a 3" outside air flex hose.
  • The term "direct-vent" means that this thimble supports exhaust venting AND an outside air connection all in one
  • Supports the outside air temperature probe for stove models with a touchscreen controller
  • Requires only one narrow opening for installation, 7 1/4"~7 1/2" square
  • Tough 316T stainless exterior with low profile intake hood
  • Can accommodate a nominal wall thickness between 4" and 10 5/8"

This wall pass-through thimble can be used for the Accentra 52i and P35i Inserts when the insert is bring installed into a an approved zero-clearance application.

P35i Zero-Clearance Box part, 1-00-774257

Accentra 52i Zero-Clearance Box part, 1-00-574205 (special Order)


Replacement For Part Number:

  • 1-00-677177

UPC: 652174680764

Technical Specs

Videos

Instructions

Install Instructions For Harman Direct Vent Wall Pass Through Thimble with OAK- 3" & 4" Pellet Vent Pipe: 1-00-677177

Click here to Download the PDF Instruction booklet with Diagrams

Locating the Passthrough on the wall

  • It would be best if none of the wall studs would need to be cut. Often you can move the unit several inches one way or the other so a stud comes to the edge of the passthrough hole.
  • Remember to allow for floor protection (hearth pad, tile, stone, etc.) when marking the center of the passthrough location.
  • Always be careful to avoid electrical wiring.
  • Decide which exterior venting configuration will be used.
  • See your Owners Manual for any code requirements that would not meet minimum venting clearance on the exterior wall.

Marking the Passthrough location on the wall

  • With the vent pipe center located, draw level/plumb cross hairs through the center line.
  • Offset these lines 3-5/8” to the top, bottom, left and right. This will create a 7-1/4” square box that becomes your through hole edges.
  • NOTE: 7-1/4” square is the minimum size hole and 7-1/2” square the maximum size hole. The intersection of the cross hairs represents the center of the PL Vent Pipe.

Cut the Hole Through the Wall

  • Never blind cut through a wall with an extended blade.
  • Always turn off power breakers for any circuits that may be passing through the wall cavity.
  • A flush-cut saw is the perfect tool for removing wallboard sections neatly and in a controlled fashion.

Install Wood Backer Strips for the Flange Mounting Screws

  • Certain types of wall construction may not provide a suitable screw backing for proper flange support. The direct vent passthrough assemblies do not fasten to each other. They slide together with a minimum of 1-1/2” overlap but require the screws in the flange for support.
  • Some types of screw backing, such as furring strips or plywood, will need to be installed on the inside of the stud cavity.
  • The direct vent wall passthrough is comprised of (3) three pieces.
  • Before starting the installation, TEST FIT THE FLANGE ASSEMBLIES together to get a better understanding of how the pieces fit together.

Installing the Outside Flange Assembly

  • It is recommended that the outside flange assembly be installed first.
  • It is extremely important that the flange is mounted level/plumb and in alignment with the unit flue outlet. The inside flange cover have little adjustment if the outside flange is installed improperly. Therefore, it is important to test fit the inside flange assembly to check for alignment before the final caulk and/or sealant is applied.
  • Combustible materials can come in contact with any of the outside surfaces of the sleeves and flanges.

Installing the Inside Flange Assembly

  • The intake pipe extension section of the flange should be installed in the upper left hand corner (for most insulations)
  • The inside flange does not need to be sealed to the wall surface, but it can be if desired
  • NOTE: The inside flange assembly may be installed in any of the (4) four positions if necessary for other then straight out the back installations.

Installing the Inside Flange Cover

  • For straight out installations, set the intake pipe number that works best for the unit being installed.
  • P43 Pellet Stove: #1-90-04300.............................. #7
  • P61A Pellet Stove: #1-90-05801 ........................... #7
  • P68 Pellet Stove: #1-70-00688.............................. #7
  • Advance Pellet Stove: #1-70-08730...................... #6
  • Accentra Pellet Stove: #1-90-02470...................... #3
  • XXV Pellet Stove: #1-90-00677............................. #2
  • PF120 Pellet Furnace: #1-90-08120 ..................... as necessary
  • HydroFlex 60 Pellet Boiler: #1-90-232000............. as necessary
  • Accentra 52i Insert: #1-90-574240*....................... as necessary
  • P35i Pellet Insert: #1-70-774235*.......................... as necessary
  • Note: ONLY when when installed with 3” pellet vent. 4" installation may require these numbers to increase by 1.

Instructions for installing the Outside Air Sensor for the Touch Control (Part #1-00-70607)

  • After the inside and outside flange are mounted but before the inside cover is mounted, the outside air sensor wire should be installed
  • Feed the sensor end of the wire up through the knockout hole located in the bottom right corner of the inside flange
  • From here, feed the wire through the hole provided just above the knockout hole
  • Run the wire along the bottom right corner of the outside flange, exiting through the knockout hole provided extending roughly 3” to the outside.
  • Install the Stainless Steel sun shield by drilling two pilot holes with an 1/8” drill bit and pop rivet the shield to the outside flange using the black pop rivets supplied
  • Complete the inside cover and Tie wrap the wire to the tabs located inside the sun shield.

Complete the Intake Flex Pipe and Venting

  • The unit can now be set into place to get the length for the intake flex pipe and for the PL vent pipe.
  • It is recommended that the flex pipe be siliconed into the pipe stub of the passthrough, but not siliconed into the unit’s intake pipe stub so that the unit can be easily moved, if necessary
  • NOTE: The PL vent pipe should be siliconed where it passes through the inside cover but it is not necessary where it passes through the outside flange, unless desired
  • NOTE: Follow the PL vent pipe manufacture’s recommendations for 3” clearances to combustibles to the point where the pipe enters and exits the Direct Vent Wall Passthrough
  • NOTE: See the Owners Manual for the unit being installed for exterior flue pipe termination restrictions
  • NOTE: The Direct Vent Wall Passthrough is only certified as a venting component if the outside air is connected to the intake pipe of the listed stoves manufactured by Hearth and Home Technologies.


Troubleshooting

  1. Never blind cut through a wall with an extended blade. Assumer there are live wires present and carefully open the wall to inspect prior to using a long plunging blade of a reciprocating saw.
  2. Flush cut saws and hole saws are a great tool for neatly removing wallboard to create an inspection hole.
  3. Always turn off electrical breakers if there are any live circuits in the wall cavity.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

This direct vent wall pass-through thimble is made by Harman and is listed as a compatible venting component for Harman pellet stoves and inserts when using Simpson Pellet Vent Pro pellet venting.

Venting and 3" OAK hose sold separately.

  • The exhaust opening will accommodate both 3" and 4" vent diameters and a 3" outside air flex hose.
  • The term "direct-vent" means that this thimble supports exhaust venting AND an outside air connection all in one
  • Supports the outside air temperature probe for stove models with a touchscreen controller
  • Requires only one narrow opening for installation, 7 1/4"~7 1/2" square
  • Tough 316T stainless exterior with low profile intake hood
  • Can accommodate a nominal wall thickness between 4" and 10 5/8"

This wall pass-through thimble can be used for the Accentra 52i and P35i Inserts when the insert is bring installed into a an approved zero-clearance application.

P35i Zero-Clearance Box part, 1-00-774257

Accentra 52i Zero-Clearance Box part, 1-00-574205 (special Order)


Replacement For Part Number:

  • 1-00-677177

UPC: 652174680764

Instructions

Assembly Instructions For Harman Direct Vent Wall Pass Through Thimble with OAK- 3" & 4" Pellet Vent Pipe: 1-00-677177

Click here to Download the PDF Instruction booklet with Diagrams

Locating the Passthrough on the wall

  • It would be best if none of the wall studs would need to be cut. Often you can move the unit several inches one way or the other so a stud comes to the edge of the passthrough hole.
  • Remember to allow for floor protection (hearth pad, tile, stone, etc.) when marking the center of the passthrough location.
  • Always be careful to avoid electrical wiring.
  • Decide which exterior venting configuration will be used.
  • See your Owners Manual for any code requirements that would not meet minimum venting clearance on the exterior wall.

Marking the Passthrough location on the wall

  • With the vent pipe center located, draw level/plumb cross hairs through the center line.
  • Offset these lines 3-5/8” to the top, bottom, left and right. This will create a 7-1/4” square box that becomes your through hole edges.
  • NOTE: 7-1/4” square is the minimum size hole and 7-1/2” square the maximum size hole. The intersection of the cross hairs represents the center of the PL Vent Pipe.

Cut the Hole Through the Wall

  • Never blind cut through a wall with an extended blade.
  • Always turn off power breakers for any circuits that may be passing through the wall cavity.
  • A flush-cut saw is the perfect tool for removing wallboard sections neatly and in a controlled fashion.

Install Wood Backer Strips for the Flange Mounting Screws

  • Certain types of wall construction may not provide a suitable screw backing for proper flange support. The direct vent passthrough assemblies do not fasten to each other. They slide together with a minimum of 1-1/2” overlap but require the screws in the flange for support.
  • Some types of screw backing, such as furring strips or plywood, will need to be installed on the inside of the stud cavity.
  • The direct vent wall passthrough is comprised of (3) three pieces.
  • Before starting the installation, TEST FIT THE FLANGE ASSEMBLIES together to get a better understanding of how the pieces fit together.

Installing the Outside Flange Assembly

  • It is recommended that the outside flange assembly be installed first.
  • It is extremely important that the flange is mounted level/plumb and in alignment with the unit flue outlet. The inside flange cover have little adjustment if the outside flange is installed improperly. Therefore, it is important to test fit the inside flange assembly to check for alignment before the final caulk and/or sealant is applied.
  • Combustible materials can come in contact with any of the outside surfaces of the sleeves and flanges.

Installing the Inside Flange Assembly

  • The intake pipe extension section of the flange should be installed in the upper left hand corner (for most insulations)
  • The inside flange does not need to be sealed to the wall surface, but it can be if desired
  • NOTE: The inside flange assembly may be installed in any of the (4) four positions if necessary for other then straight out the back installations.

Installing the Inside Flange Cover

  • For straight out installations, set the intake pipe number that works best for the unit being installed.
  • P43 Pellet Stove: #1-90-04300.............................. #7
  • P61A Pellet Stove: #1-90-05801 ........................... #7
  • P68 Pellet Stove: #1-70-00688.............................. #7
  • Advance Pellet Stove: #1-70-08730...................... #6
  • Accentra Pellet Stove: #1-90-02470...................... #3
  • XXV Pellet Stove: #1-90-00677............................. #2
  • PF120 Pellet Furnace: #1-90-08120 ..................... as necessary
  • HydroFlex 60 Pellet Boiler: #1-90-232000............. as necessary
  • Accentra 52i Insert: #1-90-574240*....................... as necessary
  • P35i Pellet Insert: #1-70-774235*.......................... as necessary
  • Note: ONLY when when installed with 3” pellet vent. 4" installation may require these numbers to increase by 1.

Instructions for installing the Outside Air Sensor for the Touch Control (Part #1-00-70607)

  • After the inside and outside flange are mounted but before the inside cover is mounted, the outside air sensor wire should be installed
  • Feed the sensor end of the wire up through the knockout hole located in the bottom right corner of the inside flange
  • From here, feed the wire through the hole provided just above the knockout hole
  • Run the wire along the bottom right corner of the outside flange, exiting through the knockout hole provided extending roughly 3” to the outside.
  • Install the Stainless Steel sun shield by drilling two pilot holes with an 1/8” drill bit and pop rivet the shield to the outside flange using the black pop rivets supplied
  • Complete the inside cover and Tie wrap the wire to the tabs located inside the sun shield.

Complete the Intake Flex Pipe and Venting

  • The unit can now be set into place to get the length for the intake flex pipe and for the PL vent pipe.
  • It is recommended that the flex pipe be siliconed into the pipe stub of the passthrough, but not siliconed into the unit’s intake pipe stub so that the unit can be easily moved, if necessary
  • NOTE: The PL vent pipe should be siliconed where it passes through the inside cover but it is not necessary where it passes through the outside flange, unless desired
  • NOTE: Follow the PL vent pipe manufacture’s recommendations for 3” clearances to combustibles to the point where the pipe enters and exits the Direct Vent Wall Passthrough
  • NOTE: See the Owners Manual for the unit being installed for exterior flue pipe termination restrictions
  • NOTE: The Direct Vent Wall Passthrough is only certified as a venting component if the outside air is connected to the intake pipe of the listed stoves manufactured by Hearth and Home Technologies.


Troubleshooting

  1. Never blind cut through a wall with an extended blade. Assumer there are live wires present and carefully open the wall to inspect prior to using a long plunging blade of a reciprocating saw.
  2. Flush cut saws and hole saws are a great tool for neatly removing wallboard to create an inspection hole.
  3. Always turn off electrical breakers if there are any live circuits in the wall cavity.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)