US Stove High Limit Snap Switch Thermodisc Manual Reset Button (L200°F): 80601

Product rating:
Product price:
$59.99
Product SKU ! 80601
Product MPN ! 80601
Product availability: In Stock
Bullet point features

Frequently Bought Together

Total Price: $277.96

Description

Replacement high temp switch w/ reset for the 5660 Bayfront pellet stove.


Replacement For Part Number:

  • 80601

View Compatible Models

UPC: 012685000787

Compatible Models

    US Stove Company

  • 5560
  • 5660

Technical Specs

Open Value L200°F
Close Value MANUAL RESET
Normal State CLOSED

Videos

Instructions

Install Instructions For US Stove High Limit Snap Switch Thermodisc Manual Reset Button (L200°F): 80601
  1. Remove unit from power
  2. Remove rear or right side access panel
  3. switch is located on rear wall of stove above room blower
  4. Remove wires
  5. Remove switch
  6. Replace with new switch and connect wires
  7. Reinstall access panels
  8. Reconnect power


Troubleshooting

This switch should be "NC" or normally closed or "ON". If the switch detects 200°F or more the switch rolls out to "OPEN" and the power is cut telling the controller to stop feeding and the room blower will run non-stop. Pressing the red button on the switch will "RESET" the switch to the NC position provided the switch's metal face is <200°F on the metal face.


High limit switches do not usually fail without some kind of event, like a power surge. Generally if the switch fails the reset button will no longer hold the switch in the normally closed position. If this has happened, it would be a good idea to remove the controller and inspect the electrical circuitry on both sides of the board for signs of a power arc or controller board component failure. IF replacing the switch does not remedy the problem, you may need a new controller.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $199!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

Replacement high temp switch w/ reset for the 5660 Bayfront pellet stove.


Replacement For Part Number:

  • 80601

View Compatible Models

UPC: 012685000787

Technical Specs

Open Value L200°F
Close Value MANUAL RESET
Normal State CLOSED

Instructions

Assembly Instructions For US Stove High Limit Snap Switch Thermodisc Manual Reset Button (L200°F): 80601

  1. Remove unit from power
  2. Remove rear or right side access panel
  3. switch is located on rear wall of stove above room blower
  4. Remove wires
  5. Remove switch
  6. Replace with new switch and connect wires
  7. Reinstall access panels
  8. Reconnect power


Troubleshooting

This switch should be "NC" or normally closed or "ON". If the switch detects 200°F or more the switch rolls out to "OPEN" and the power is cut telling the controller to stop feeding and the room blower will run non-stop. Pressing the red button on the switch will "RESET" the switch to the NC position provided the switch's metal face is <200°F on the metal face.


High limit switches do not usually fail without some kind of event, like a power surge. Generally if the switch fails the reset button will no longer hold the switch in the normally closed position. If this has happened, it would be a good idea to remove the controller and inspect the electrical circuitry on both sides of the board for signs of a power arc or controller board component failure. IF replacing the switch does not remedy the problem, you may need a new controller.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $199!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 3 reviews
100%
(3)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
A
Anonymous
Ok

The part is going to be a back up.

A
Anonymous
Part for my stove

The part we ordered was exactly what we needed. Thank You

J
Justin S.
perfect fit

perfect fit and replacement of original switch took 2 minutes to install great quality and super fast shipping

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form
Ask a Question
  • The high temp limit switch was tripped. The blower doesn’t want to run and makes a shrill tearing(?)sound. Which is actually bad?

    Sounds like the Convection blower. The high limit shuts down the stove if it gets too hot. The convection/room air blower has two functions. One, to push the heat the body of the stove is radiating out into the room and two, to cool down the body of the stove. The function of the high limit switch is to shut the stove down if  it senses that the body of the stove is reaching 250 degrees. This is to prevent damage from occuring from overheating. If the convection blower is not spinning fast enough or not spinning at all, it is no longer able to get the heat away from the stove to keep it from over heating, this will trigger the high limit switch to shut the stove down.

  • does this switch control the blower to start up and blow air

    Yes. This is the safety high limit switch. It will shut the stove off if the temperature reaches 200 degrees. The function of the convection blower/ room air blower is 1) to blower hot air into the room and, 2) to cool off the body of the stove so it does not over heat. If this blower is not working properly the stove will get too hot. Once it reaches 200 degrees the high limit switch will shut down the stove before any permanent damage can happen

Customer Reviews

Based on 3 reviews
100%
(3)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
A
Anonymous
Ok

The part is going to be a back up.

A
Anonymous
Part for my stove

The part we ordered was exactly what we needed. Thank You

J
Justin S.
perfect fit

perfect fit and replacement of original switch took 2 minutes to install great quality and super fast shipping