Skip to main content
Skip to main content
Product title:

Enviro Combustion Blower Mounting Gasket: EF-011

Product rating:
Product price:
$8.99
Product SKU ! EF-011
Product MPN ! EF-011
Product availability: In Stock
Bullet point features
  • Replaces Part # EF-011 for many Enviro models
  • Easy Do-It-Yourself Install
  • Seals Between The Exhaust Blower Housing And The Unit
  • Measures 8 ½" Long, 6 ½" Wide, and ³⁄₁₆" Thick
  • FREE Shipping with orders over $99
  • 30-Day Hassle Free Returns
  • 90-Day Warranty Included With Purchase
  • Same Day Shipping On Most Items!*
  • See Complete Description
Buy Now Pay Later

Have a Question? Contact Us 24/7 to Ask a Specialist

  • FREE Shipping

    Orders over $99

  • 30-Day Returns

    Hassle free return policy

  • 90-Day Warranty

    Included with purchase

  • Same-Day Shipping

    On most items*

Description

Replacement Enviro Combustion Blower Mounting Gasket for Select Enviro Stoves, See Compatible. 



Replacement For Part Number:

  • EF-011

Technical Specs

Length (in) 8 ½"
Width (in) 6 ½"
Height (in) .1"
Inner Diameter (in) 4 ⅞"
Thickness (in) 0.188"
Weight .25 oz

Instructions

Install Instructions For Enviro Combustion Blower Mounting Gasket: EF-011
  1. Unplug the unit.
  2. Remove the necessary panels to access the blower and disconnect the venting. This may require removal of the rear and side panels.
  3. Locate the exhaust blower assembly.
  4. Loosen the bolts attaching the housing to the stove. You may be able to support the blower during this step. If there is not enough slack in the leads running to the blower or any low-limit switch attached to the blower housing, disconnect the wires at this time.
  5. Remove the old gasket.
  6. Position the new gasket in place, line up your blower, and start to thread the previously removed bolts into place and tighten completely.
  7. Reattach any previously disconnected wires.
  8. Reinstall the venting and vent adapter (if they were previously removed).
  9. Install any previously removed panels.
  10. Plug in the unit and test the blower.



NOTE: If the venting was removed, make sure to apply high-temperature RTV silicone at the connection point when reinstalling and replace any previously removed screws. If the venting adapter was removed from the blower housing, make sure this connection point is also sealed with a high temp silicone and secured with the proper self-tapping screw(s).

Troubleshooting

This gasket seals between the exhaust blower housing and the unit. It is important to inspect this seal periodically to make sure it is in good shape. If the gasket shows signs of deterioration or you notice stains on the gasket it should be replaced. Running your stove with a bad gasket may allow smoke to enter the room.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package. Please note, we are unable to track US Postal packages once they cross the US border and cannot guarantee shipping times. All customs fees incurred are the responsibility of the customer and are not included in the total price. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

Replacement Enviro Combustion Blower Mounting Gasket for Select Enviro Stoves, See Compatible. 



Replacement For Part Number:

  • EF-011

Technical Specs

Length (in) 8 ½"
Width (in) 6 ½"
Height (in) .1"
Inner Diameter (in) 4 ⅞"
Thickness (in) 0.188"
Weight .25 oz

Instructions

Install Instructions For Enviro Combustion Blower Mounting Gasket: EF-011
  1. Unplug the unit.
  2. Remove the necessary panels to access the blower and disconnect the venting. This may require removal of the rear and side panels.
  3. Locate the exhaust blower assembly.
  4. Loosen the bolts attaching the housing to the stove. You may be able to support the blower during this step. If there is not enough slack in the leads running to the blower or any low-limit switch attached to the blower housing, disconnect the wires at this time.
  5. Remove the old gasket.
  6. Position the new gasket in place, line up your blower, and start to thread the previously removed bolts into place and tighten completely.
  7. Reattach any previously disconnected wires.
  8. Reinstall the venting and vent adapter (if they were previously removed).
  9. Install any previously removed panels.
  10. Plug in the unit and test the blower.



NOTE: If the venting was removed, make sure to apply high-temperature RTV silicone at the connection point when reinstalling and replace any previously removed screws. If the venting adapter was removed from the blower housing, make sure this connection point is also sealed with a high temp silicone and secured with the proper self-tapping screw(s).

Troubleshooting

This gasket seals between the exhaust blower housing and the unit. It is important to inspect this seal periodically to make sure it is in good shape. If the gasket shows signs of deterioration or you notice stains on the gasket it should be replaced. Running your stove with a bad gasket may allow smoke to enter the room.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package. Please note, we are unable to track US Postal packages once they cross the US border and cannot guarantee shipping times. All customs fees incurred are the responsibility of the customer and are not included in the total price. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customers Also Bought

  • SKU
    MPN
    PP7900-2
    EF-008
    $24.99
    Enviro Exhaust Impeller Blade (4 1/2"): EF-008-AMP

    Enviro Exhaust Impeller Blade (4 1/2"): EF-008-AMP

    Replaces EF-008
  • SKU
    MPN
    EF-018-SVH
    EF-018
    $14.99
    Enviro Pellet Stove Silicone Vacuum Hose (12"): EF-018

    Enviro Pellet Stove Silicone Vacuum Hose (12"): EF-018

  • SKU
    MPN
    700N-CW-5
    EF-001
    $89.99
    Enviro Auger Motor: EF-001-AMP

    Enviro Auger Motor: EF-001-AMP

    1RPM Clockwise 1 RPM CW
  • SKU
    MPN
    PP3342-1
    EC-001
    $34.99
    Enviro Low Limit Heat Temp Sensor (120°): EC-001-AMP

    Enviro Low Limit Heat Temp Sensor (120°): EC-001-AMP

    Normally Open: Normally°/120° Replaces EC-001
  • SKU
    EC-058
    $29.99
    Enviro Glass Gasket (72 Inches Long): EC-058

    Enviro Glass Gasket (72 Inches Long): EC-058

    84" L x .625" W x .1" H Fiberglass
  • SKU
    EF-126
    $49.99
    Enviro Firebox Ceramic Wool Insulation: EF-126

    Enviro Firebox Ceramic Wool Insulation: EF-126

    12 1/2" x 7 1/2" x1" 2 1/2" diameter hole
  • SKU
    50-619-AMP
    $49.99
    Enviro Igniter (400W): 50-619-AMP

    Enviro Igniter (400W): 50-619-AMP

    115V / 400W 5" L
  • SKU
    EF-052-AMP
    $35.99
    $39.99
    Enviro Igniter Cartridge Heater 200W (Pre July 1994): EF-052

    Enviro Igniter Cartridge Heater 200W (Pre July 1994): EF-052

    115V / 200W 6 ⅛" L
  • SKU
    50-833
    $3.99
    Enviro 5amp Control Board Fuse: 50-833

    Enviro 5amp Control Board Fuse: 50-833

    125V / 5A
  • SKU
    SP4L-101-4
    $129.99
    Enviro Combustion Blower Motor Only: EF-161-AMP

    Enviro Combustion Blower Motor Only: EF-161-AMP

    115V / 1.6A 3000 RPM
  • SKU
    EF-045-AMP
    $49.99
    Enviro Fan Controller Rheostat with Knob (115V): EF-045-AMP

    Enviro Fan Controller Rheostat with Knob (115V): EF-045-AMP

  • SKU
    SP4L-151-2
    $229.99
    Enviro Convection Blower By Fasco: EF-002-AMP

    Enviro Convection Blower By Fasco: EF-002-AMP

    115V / 1.5A 3000 RPM

Customer Reviews

Based on 93 reviews
98%
(91)
2%
(2)
0%
(0)
0%
(0)
0%
(0)
C
Charles K.

St. Croix Combustion Fan Gasket: 80P20168-R

C
Chris B.

Easy to order and fast shipping. Priced great

H
Heather P.
Review

We always get our order in great time!

M
Michael E.S.S.
Whitefield Exhaust Blower Gasket

Exact fit ! Placed and installed new exhaust blower motor. Worked perfectly.

D
Danny C.

Excellent product

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 93 reviews
98%
(91)
2%
(2)
0%
(0)
0%
(0)
0%
(0)
C
Charles K.

St. Croix Combustion Fan Gasket: 80P20168-R

C
Chris B.

Easy to order and fast shipping. Priced great

H
Heather P.
Review

We always get our order in great time!

M
Michael E.S.S.
Whitefield Exhaust Blower Gasket

Exact fit ! Placed and installed new exhaust blower motor. Worked perfectly.

D
Danny C.

Excellent product