Pellet Stove Vent Pipe Kit With 4 Inch Horizontal Pipe With Dura Vent Pro: 4PVP-HZ-KIT
Product price:- Ships FREE with orders over $49
- 30-Day Hassle Free Returns
- 90 Day Warranty Included
- Same Day Shipping On Most Items!*
- See Complete Description
This 4-inch installation kit contains everything you need to vent your pellet stove straight out the wall. Our kits use only the highest quality Pellet Vent Pro venting by DuraVent, but at affordable bundle pricing, so you save big!
An additional 45° Elbow can be purchased if your stove is installed in a corner. Use part # 4PVP-E45.
Included In This Kit:
This kit uses aftermarket parts where applicable to help you save big!
The pellet venting we sell is Dura-Vent Pellet Vent Pro. Pellet Vent Pro is a twist-lock pellet vent that has an integrated silicon seal within the vent. Simpson Dura-Vent, the pellet venting available in home stores like Home Depot and Lowe's (and we do not sell) is a lower grade pellet venting without the integrated silicon seal. THESE VENTING TYPES ARE MADE BY THE SAME MANUFACTURER BUT THEY CANNOT BE USED TOGETHER AND ARE NOT COMPATIBLE.
General Installation Instructions:
In addition, the following must be observed:
A. The clearance above grade must be a minimum of 12".
B. The clearance to a window or door that may be opened must be a minimum of 48" to the side, 48" below the window/door, 12" above the window/door. (with outside air installed, 9” to the side and below)
C. A 12" clearance to a permanently closed window is recommended to prevent condensation on the window.
D. The vertical clearance to a vented soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the center-line of the terminal must be a minimum of 18".
E. The clearance to an non-vented soffit must be a minimum of 12".
F. The clearance to an outside corner is 11" from the center of the pipe.
G. The clearance to an inside corner is 12".
H. A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when measured from the horizontal center-line of the regulator.
I. The clearance to service regulator vent outlet must be a minimum of 6 feet.
J. The clearance to a non-mechanical air supply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48”.
K. The clearance to a mechanical air supply inlet must be a minimum of 10 feet. (with outside air installed, 6 feet)
L. The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet.
M. The clearance under a veranda, porch, deck or balcony must be a minimum of 12 inches. (B. also)
NOTE: The clearance to vegetation and other exterior combustibles such as mulch is 36” as measured from the center of the outlet or cap. This 36” radius continues to grade.
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single-family dwellings and serves both dwellings. Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor.
How to Determine Venting Diameter?
When trying to figure out what size venting is best for your install, follow each of these rules. If none of these rules apply you’re good to use 3” venting.
Rule 1: The appliance collar, appliance take-off, tailpipe, or exhaust stub are a few of the common names for the stove’s exhaust connection. Measure the outside diameter of this connection. Most are 3 inches but some are 4 inches. This is the MINIMUM venting size approved for your stove you cannot reduce down to 3” if you have a 4” collar.
Rule 2: As a general rule, if the total lineal feet of your proposed venting is more than 20 feet, do not use 3-inch venting. Increase to 4 inches as close to the stove as possible.
Rule 3: Equivalent Vent Length Determination (EVL) - All venting components restrict airflow so accommodations must be made for turns and lengths of venting. This also determines whether 3” diameter is sufficient
90° Turns are equal to 5
45° Turns are equal to 3
The total horizontal feet are multiplied by 1
The total vertical feet are multiplied by 0.5
If the sum of these parts equals more than 15, this particular installation requires 4” venting.
General Installation Rules:
Before You Start Cutting Holes Through a Wall or Ceiling
A great install is not only functional and safe but is also aesthetically pleasing. Making it look good often requires a very strong working knowledge within the limitations of venting components. Understanding how they piece together isn’t something they teach you in the NFI exam, so here’s how I do it.
This Item Qualifies For Free Shipping!
When Will My Order Ship?
All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.
Do You Offer Express Shipping?
Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.
How Does Free Shipping Work?
Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.
Do You Ship To Canada?
We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.
Do You Ship To Alaska Or Hawaii?
We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.
Do You Ship Outside The US Or Canada?
Unfortunately, at this time we do not offer international shipping other than to Canada.
Shipping Time Estimations
For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.
This 4-inch installation kit contains everything you need to vent your pellet stove straight out the wall. Our kits use only the highest quality Pellet Vent Pro venting by DuraVent, but at affordable bundle pricing, so you save big!
An additional 45° Elbow can be purchased if your stove is installed in a corner. Use part # 4PVP-E45.
Included In This Kit:
This kit uses aftermarket parts where applicable to help you save big!
The pellet venting we sell is Dura-Vent Pellet Vent Pro. Pellet Vent Pro is a twist-lock pellet vent that has an integrated silicon seal within the vent. Simpson Dura-Vent, the pellet venting available in home stores like Home Depot and Lowe's (and we do not sell) is a lower grade pellet venting without the integrated silicon seal. THESE VENTING TYPES ARE MADE BY THE SAME MANUFACTURER BUT THEY CANNOT BE USED TOGETHER AND ARE NOT COMPATIBLE.
General Installation Instructions:
In addition, the following must be observed:
A. The clearance above grade must be a minimum of 12".
B. The clearance to a window or door that may be opened must be a minimum of 48" to the side, 48" below the window/door, 12" above the window/door. (with outside air installed, 9” to the side and below)
C. A 12" clearance to a permanently closed window is recommended to prevent condensation on the window.
D. The vertical clearance to a vented soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the center-line of the terminal must be a minimum of 18".
E. The clearance to an non-vented soffit must be a minimum of 12".
F. The clearance to an outside corner is 11" from the center of the pipe.
G. The clearance to an inside corner is 12".
H. A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when measured from the horizontal center-line of the regulator.
I. The clearance to service regulator vent outlet must be a minimum of 6 feet.
J. The clearance to a non-mechanical air supply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48”.
K. The clearance to a mechanical air supply inlet must be a minimum of 10 feet. (with outside air installed, 6 feet)
L. The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet.
M. The clearance under a veranda, porch, deck or balcony must be a minimum of 12 inches. (B. also)
NOTE: The clearance to vegetation and other exterior combustibles such as mulch is 36” as measured from the center of the outlet or cap. This 36” radius continues to grade.
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single-family dwellings and serves both dwellings. Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor.
How to Determine Venting Diameter?
When trying to figure out what size venting is best for your install, follow each of these rules. If none of these rules apply you’re good to use 3” venting.
Rule 1: The appliance collar, appliance take-off, tailpipe, or exhaust stub are a few of the common names for the stove’s exhaust connection. Measure the outside diameter of this connection. Most are 3 inches but some are 4 inches. This is the MINIMUM venting size approved for your stove you cannot reduce down to 3” if you have a 4” collar.
Rule 2: As a general rule, if the total lineal feet of your proposed venting is more than 20 feet, do not use 3-inch venting. Increase to 4 inches as close to the stove as possible.
Rule 3: Equivalent Vent Length Determination (EVL) - All venting components restrict airflow so accommodations must be made for turns and lengths of venting. This also determines whether 3” diameter is sufficient
90° Turns are equal to 5
45° Turns are equal to 3
The total horizontal feet are multiplied by 1
The total vertical feet are multiplied by 0.5
If the sum of these parts equals more than 15, this particular installation requires 4” venting.
General Installation Rules:
Before You Start Cutting Holes Through a Wall or Ceiling
A great install is not only functional and safe but is also aesthetically pleasing. Making it look good often requires a very strong working knowledge within the limitations of venting components. Understanding how they piece together isn’t something they teach you in the NFI exam, so here’s how I do it.
This Item Qualifies For Free Shipping!
When Will My Order Ship?
All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.
Do You Offer Express Shipping?
Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.
How Does Free Shipping Work?
Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.
Do You Ship To Canada?
We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.
Do You Ship To Alaska Or Hawaii?
We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.
Do You Ship Outside The US Or Canada?
Unfortunately, at this time we do not offer international shipping other than to Canada.
Shipping Time Estimations
For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.
Be the first to ask a question about this.