Bullet point features

Description

USSC Pellet Stove Vacuum/Pressure Switch.  The vacuum switch is an important safety device that ensures a certain pressure is maintained inside the stove.  This switch is mounted on the rear of the unit and will be connected to a plastic or silicon hose.  If the switch is damaged or not functioning properly it may cause the feed motor to stop turning, an error code to display or not allow the unit to feed fuel during start up.  

Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.



Replacement For Part Numbers:

  • 80621
  • C-E-201

View Compatible Models

UPC: 012685005270

Compatible Models

    Golden Eagle

  • 5520

    US Stove Company

  • 5520

    King

  • KP130
  • KP60

Technical Specs

Height 3.11''
Width 3.15''
Depth 1.06''
Water Column 0.10"
Connectors (2) 1/4" Male Spades

Instructions

Install Instructions For US Stove Vacuum/Pressure Switch: 80621-AMP

1.) Unplug the stove.

2.) Remove the necessary panels to gain access to the rear of the unit.

3.) Locate the vacuum/pressure switch (Pay attention to what port the hose connects to on the switch. Some units may have a switch with two ports on it. The hose must be installed on the correct port in order to function properly).

4.) Disconnect the vacuum hose from the switch.

5.) Remove the old switch.

6.) Install the new switch and reconnect the vacuum hose.

7.) Reinstall any previously removed panels and plug in the unit.

Troubleshooting

-To test the vacuum/pressure switch, disconnect the air hose from the body of the stove. With the other end still attached to the air switch, very gently create suction on the loose end of the hose (You may want to remove the hose entirely from the port on the stove and the air switch first to make sure it is clear). If you hear a click, the air switch is working (Be careful during this step. Creating too much negative pressure can damage the switch).


-If the switch appears to be operating correctly but you are still receiving a vacuum-related error code make sure to check:

1.) All gaskets are in good condition.

2.) The main load door and ash door are closing correctly.

3.) There are no obstructions in the exhaust vent or combustion blower.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

USSC Pellet Stove Vacuum/Pressure Switch.  The vacuum switch is an important safety device that ensures a certain pressure is maintained inside the stove.  This switch is mounted on the rear of the unit and will be connected to a plastic or silicon hose.  If the switch is damaged or not functioning properly it may cause the feed motor to stop turning, an error code to display or not allow the unit to feed fuel during start up.  

Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.



Replacement For Part Numbers:

  • 80621
  • C-E-201

View Compatible Models

UPC: 012685005270

Technical Specs

Height 3.11''
Width 3.15''
Depth 1.06''
Water Column 0.10"
Connectors (2) 1/4" Male Spades

Instructions

Install Instructions For US Stove Vacuum/Pressure Switch: 80621-AMP

1.) Unplug the stove.

2.) Remove the necessary panels to gain access to the rear of the unit.

3.) Locate the vacuum/pressure switch (Pay attention to what port the hose connects to on the switch. Some units may have a switch with two ports on it. The hose must be installed on the correct port in order to function properly).

4.) Disconnect the vacuum hose from the switch.

5.) Remove the old switch.

6.) Install the new switch and reconnect the vacuum hose.

7.) Reinstall any previously removed panels and plug in the unit.

Troubleshooting

-To test the vacuum/pressure switch, disconnect the air hose from the body of the stove. With the other end still attached to the air switch, very gently create suction on the loose end of the hose (You may want to remove the hose entirely from the port on the stove and the air switch first to make sure it is clear). If you hear a click, the air switch is working (Be careful during this step. Creating too much negative pressure can damage the switch).


-If the switch appears to be operating correctly but you are still receiving a vacuum-related error code make sure to check:

1.) All gaskets are in good condition.

2.) The main load door and ash door are closing correctly.

3.) There are no obstructions in the exhaust vent or combustion blower.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 16 reviews
100%
(16)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
S
Steve c.

Breckwell Vacuum/Pressure Switch: C-E-201-AMP

R
Rick B.
Great website

I just thought it should be mentioned their website is very informative on getting the correct parts and the instructional video's were very helpful.

T
Thomas Y.
Vacuum/pressure switch replacement

Was having stove shut down problems and replacing this unit cured the problem.

C
Claudia W.
Great service

Thank you for helping us fix our pellet stove.

F
Festim E.
🌟🌟🌟🌟🌟

Fast simple great feed back

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 16 reviews
100%
(16)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
S
Steve c.

Breckwell Vacuum/Pressure Switch: C-E-201-AMP

R
Rick B.
Great website

I just thought it should be mentioned their website is very informative on getting the correct parts and the instructional video's were very helpful.

T
Thomas Y.
Vacuum/pressure switch replacement

Was having stove shut down problems and replacing this unit cured the problem.

C
Claudia W.
Great service

Thank you for helping us fix our pellet stove.

F
Festim E.
🌟🌟🌟🌟🌟

Fast simple great feed back

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid