Skip to main content
Skip to main content
Product title:

Lennox Convection Room Air Blower: H7309-AMP

Product rating:
Product price:
$159.99

A $120.00 Savings over the OEM

Product SKU ! SP4L-151-8
Product MPN ! H7309
Product availability: In Stock
Bullet point features

Frequently Bought Together

Total Price: $179.98

Description

Replacement convection fan assembly for the Lennox Montage pellet stove. The convection fan is the blower which pushes hot air out of your stove and into your room. Also called a room air blower.


Replacement For Part Number:

  • H7309

View Compatible Models

Compatible Models

    Lennox

  • Montage

Technical Specs

RPM 3000
Amps 1.5
Volts 115
Cycles 60Hz
Wiring Connectors 1/4" Female

Instructions

Install Instructions For Lennox Convection Room Air Blower: H7309-AMP

Whether you are replacing the blower with the OEM part H7309 or our after market version H7309-AMP, the process for this repair is going to be the same.


The room blower or convection blower is located on the left side of the stove, directly behind the controller. You may be able to perform this repair entirely through the access panel on the left-side of the stove but for this video, we will remove the rear panel so you can have a clear view of the part locations.


Before performing ANY work to your stove, always unplug the stove from the power source prior to removing or opening any of the service panels.


If you want to spin your stove around for better access, you can disconnect the vent from the stove by removing the four 1/8” allan key screws that secure the appliance collar/ tailpipe to the stove. This is a recommended way to separate the vent from the stove because it preserves the seal on the vent. We sell additional gaskets, part # 61050016. This will accommodate both 3” and 4” venting connections.



  • To remove the rear panel, locate the four 1/4” hex screws .that secure the panel. You only need to loosen them a few turns and then lift the panel over the screw heads.
  • Looking from the rear, the blower is located on the right side.
  • Against the back rail, locate the white power socket and disconnect it. Additionally, if there are any zip-tie fasteners securing the slack of the wire leading to the blower, make sure to cut those so the blower can be removed.
  • Once the blower’s wire are free, locate the mounting screws for the blower. They will be at the base of motor’s mounting flange against the stove. There are 4 of them, one in each corner on the top an bottom and use a 1/8” Allan key fitting
  • Because of the tight work area, a drive socket with. Long extensions is recommended. To avoid stripping the screws, always use hand tools to remove the screws.
  • Once the screws have been removed, lift the blower out of the stove from the side panel. Because of the tight clearances, the blower will be taken out of the stove from the side service panel.
  • Install your new blower into the stove
  • When reconnecting, make sure to start each screw into the stove by hand so they do not become cross-threaded. Using your socket driver, tighten each screw by hand until snug
  • Reconnect the wires into the power jack and make sure any loose wires from the blower are free and clear of any moving parts.
  • Reattach the the rear service panel and tighten the four screws that secure the Rea panel.
  • If you disconnected your stove from the vent, turn the stove back into position and secure the appliance collar back to the exhaust mount
  • Plug in your stove and you’re done.

Troubleshooting

If your blower is buzzing or vibrating when it's on, remove it and look inside at the blower wheel, you may have something foreign caught in the blower wheel, such as a pellet. Hair and other debris should be removed from the blower wheel at least once a year. Symptoms of a poorly performing blower will be excessive noise, vibration or heat. If the blower is clean and you are still experiencing problems, replace the blower. In rare instances, the control board may be sending a modified waveform to the blower. If you replace the blower and the vibrations or excessive heat are still present, replace your controller.


Current versions of the H7309 blower are a sealed bearing that requires no lubrication, though from time to time we do see parts come in from the manufacturer that are made to the original spec that requires lubrication. This will be indicated on the listing table attached to the blower.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

Replacement convection fan assembly for the Lennox Montage pellet stove. The convection fan is the blower which pushes hot air out of your stove and into your room. Also called a room air blower.


Replacement For Part Number:

  • H7309

View Compatible Models

Technical Specs

RPM 3000
Amps 1.5
Volts 115
Cycles 60Hz
Wiring Connectors 1/4" Female

Instructions

Install Instructions For Lennox Convection Room Air Blower: H7309-AMP

Whether you are replacing the blower with the OEM part H7309 or our after market version H7309-AMP, the process for this repair is going to be the same.


The room blower or convection blower is located on the left side of the stove, directly behind the controller. You may be able to perform this repair entirely through the access panel on the left-side of the stove but for this video, we will remove the rear panel so you can have a clear view of the part locations.


Before performing ANY work to your stove, always unplug the stove from the power source prior to removing or opening any of the service panels.


If you want to spin your stove around for better access, you can disconnect the vent from the stove by removing the four 1/8” allan key screws that secure the appliance collar/ tailpipe to the stove. This is a recommended way to separate the vent from the stove because it preserves the seal on the vent. We sell additional gaskets, part # 61050016. This will accommodate both 3” and 4” venting connections.



  • To remove the rear panel, locate the four 1/4” hex screws .that secure the panel. You only need to loosen them a few turns and then lift the panel over the screw heads.
  • Looking from the rear, the blower is located on the right side.
  • Against the back rail, locate the white power socket and disconnect it. Additionally, if there are any zip-tie fasteners securing the slack of the wire leading to the blower, make sure to cut those so the blower can be removed.
  • Once the blower’s wire are free, locate the mounting screws for the blower. They will be at the base of motor’s mounting flange against the stove. There are 4 of them, one in each corner on the top an bottom and use a 1/8” Allan key fitting
  • Because of the tight work area, a drive socket with. Long extensions is recommended. To avoid stripping the screws, always use hand tools to remove the screws.
  • Once the screws have been removed, lift the blower out of the stove from the side panel. Because of the tight clearances, the blower will be taken out of the stove from the side service panel.
  • Install your new blower into the stove
  • When reconnecting, make sure to start each screw into the stove by hand so they do not become cross-threaded. Using your socket driver, tighten each screw by hand until snug
  • Reconnect the wires into the power jack and make sure any loose wires from the blower are free and clear of any moving parts.
  • Reattach the the rear service panel and tighten the four screws that secure the Rea panel.
  • If you disconnected your stove from the vent, turn the stove back into position and secure the appliance collar back to the exhaust mount
  • Plug in your stove and you’re done.

Troubleshooting

If your blower is buzzing or vibrating when it's on, remove it and look inside at the blower wheel, you may have something foreign caught in the blower wheel, such as a pellet. Hair and other debris should be removed from the blower wheel at least once a year. Symptoms of a poorly performing blower will be excessive noise, vibration or heat. If the blower is clean and you are still experiencing problems, replace the blower. In rare instances, the control board may be sending a modified waveform to the blower. If you replace the blower and the vibrations or excessive heat are still present, replace your controller.


Current versions of the H7309 blower are a sealed bearing that requires no lubrication, though from time to time we do see parts come in from the manufacturer that are made to the original spec that requires lubrication. This will be indicated on the listing table attached to the blower.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 137 reviews
96%
(132)
4%
(5)
0%
(0)
0%
(0)
0%
(0)
J
Joe k.

Great company to work with. Great

P
Peter D.

Very good service. Good prices. I will buy more parts from you as I need them.
Thank you.

G
Gregg J.
Vogelzang Room Blower

Great, speedy service & delivery. Simple switch out and is working like a charm, thanks!

J
Josie F.

Excellent service and correct product. Never had a problem. Keep up the good work.

T
Tim W.
Great service as usual

Yes as usual (which is hard to come by these days) fast & easy. Thank you

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 137 reviews
96%
(132)
4%
(5)
0%
(0)
0%
(0)
0%
(0)
J
Joe k.

Great company to work with. Great

P
Peter D.

Very good service. Good prices. I will buy more parts from you as I need them.
Thank you.

G
Gregg J.
Vogelzang Room Blower

Great, speedy service & delivery. Simple switch out and is working like a charm, thanks!

J
Josie F.

Excellent service and correct product. Never had a problem. Keep up the good work.

T
Tim W.
Great service as usual

Yes as usual (which is hard to come by these days) fast & easy. Thank you

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid