Ashley (Wood/Coal) Furnace Limit Control: 80145

Product rating:
Product price:
$189.99
Product SKU ! 80145(ASH)
Product MPN ! AC-1339
Product availability: In Stock
Bullet point features
Buy Now Pay Later

Description

Ashley (Wood/Coal) Furnace High Limit Control: 80145.  This switch allows blowers on the furnace to cycle on and off based on the internal temperature of the unit.  If you have blowers that are constantly running or will not kick on once the furnace is up to operating temperature, this could indicate that the limit switch has failed. 

 


Replacement For Part Number:

  • AC-1339

UPC: 012685801452

Compatible Models

Technical Specs

Length 8.25''
Width 7.5''
Height 4.5''
Probe Length 5.13''
Probe Diameter 3/4''
Maximum Temperature 800° F | 426° C
Material Cast Iron

Instructions

Install Instructions For Ashley (Wood/Coal) Furnace Limit Control: 80145

Distribution Blower & Accessories: Blowers, Limit Control, Fan Center

1. Ensure that all components are present for assembly.

2. Begin by attaching the blowers to the unit. Insert a clip into each mounting hole in the furnace’s cabinet back. Be sure to install the gasket between the blower and cabinet back. Insert the eight bolts provided and tighten.

3. Mount the limit control to the cabinet back. The conduit assembly should already be attached to the limit control; if not, attach it, then make the correct wiring connections to the limit control. (See wiring diagram for your unit).

4. Next, mount the junction box and insulation using two #10 x 1/2 screws. Make a small slice in the 5 x 5 insulation to allow the wires from the draft blower to protrude, then install it between the cabinet back and junction box, with the foil side to the cabinet back. Attach the conduit assembly from the limit control to the junction box as shown.

5. If not already installed, snap the rocker switch into the top of the junction box. Provide a 110 volt power supply and connect to the junction box with the cable clamp to the right side.

6. Attach the two longer conduit assemblies to the junction box and to each blower.

7. Before mounting the Fan Center, make all the wire connections per the wiring diagram, then attach the fan center to the junction box (A qualified electrician should do all electrical connections).

Troubleshooting

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package. Please note, we are unable to track US Postal packages once they cross the US border and cannot guarantee shipping times. All customs fees incurred are the responsibility of the customer and are not included in the total price. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

Ashley (Wood/Coal) Furnace High Limit Control: 80145.  This switch allows blowers on the furnace to cycle on and off based on the internal temperature of the unit.  If you have blowers that are constantly running or will not kick on once the furnace is up to operating temperature, this could indicate that the limit switch has failed. 

 


Replacement For Part Number:

  • AC-1339

UPC: 012685801452

Technical Specs

Length 8.25''
Width 7.5''
Height 4.5''
Probe Length 5.13''
Probe Diameter 3/4''
Maximum Temperature 800° F | 426° C
Material Cast Iron

Instructions

Install Instructions For Ashley (Wood/Coal) Furnace Limit Control: 80145

Distribution Blower & Accessories: Blowers, Limit Control, Fan Center

1. Ensure that all components are present for assembly.

2. Begin by attaching the blowers to the unit. Insert a clip into each mounting hole in the furnace’s cabinet back. Be sure to install the gasket between the blower and cabinet back. Insert the eight bolts provided and tighten.

3. Mount the limit control to the cabinet back. The conduit assembly should already be attached to the limit control; if not, attach it, then make the correct wiring connections to the limit control. (See wiring diagram for your unit).

4. Next, mount the junction box and insulation using two #10 x 1/2 screws. Make a small slice in the 5 x 5 insulation to allow the wires from the draft blower to protrude, then install it between the cabinet back and junction box, with the foil side to the cabinet back. Attach the conduit assembly from the limit control to the junction box as shown.

5. If not already installed, snap the rocker switch into the top of the junction box. Provide a 110 volt power supply and connect to the junction box with the cable clamp to the right side.

6. Attach the two longer conduit assemblies to the junction box and to each blower.

7. Before mounting the Fan Center, make all the wire connections per the wiring diagram, then attach the fan center to the junction box (A qualified electrician should do all electrical connections).

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package. Please note, we are unable to track US Postal packages once they cross the US border and cannot guarantee shipping times. All customs fees incurred are the responsibility of the customer and are not included in the total price. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 11 reviews
91%
(10)
9%
(1)
0%
(0)
0%
(0)
0%
(0)
W
William T.R.R.

US Stove Limit control: 80145

K
Kent N.J.
Stove fan

Everything went back just like the factory parts

S
Steven D.
Thermostat for Englander wood furnace.

Exactly what I needed and ship time was sooner than I expected. Cost was reasonable, free shipping.
Completely satisfied.

R
Richard M.

Fast and dependable

J
Joseph M.
great service - quick to ship, quick to respond

It's winter and I needed a part for my furnace.
It was the exact replacement, and they shipped it right out.
It was packed safe, and installed quick.
I was back in heat.
Thank you.

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 11 reviews
91%
(10)
9%
(1)
0%
(0)
0%
(0)
0%
(0)
W
William T.R.R.

US Stove Limit control: 80145

K
Kent N.J.
Stove fan

Everything went back just like the factory parts

S
Steven D.
Thermostat for Englander wood furnace.

Exactly what I needed and ship time was sooner than I expected. Cost was reasonable, free shipping.
Completely satisfied.

R
Richard M.

Fast and dependable

J
Joseph M.
great service - quick to ship, quick to respond

It's winter and I needed a part for my furnace.
It was the exact replacement, and they shipped it right out.
It was packed safe, and installed quick.
I was back in heat.
Thank you.