Install Instructions For Breckwell (Multi-Fuel) Furnace Exhaust Blower Assembly: 80495-AMP
1.) Unplug the unit and make sure it is cool to the touch.
2.) Remove the necessary panels from the furnace (You may need to remove the rear and side panels).
3.) Next, remove or unplug your RDT temp sensor and disconnect the power wires leading to the draft blower.
4.) Remove the screws attaching the blower housing to the unit and remove the blower assembly (You may need to disconnect the exhaust pipe from the unit).
5.) Remove the old gasket (Using a flathead screwdriver, scrape and remove any pieces of old gasket stuck to the housing or body of the unit).
6.) Position the new gasket in place.
7.) Set the new assembly in place and reinstall the previously removed screws.
8.) Reconnect the RDT temp sensor and power wires.
9.) Reconnect and seal the exhaust (If it was removed) & reinstall any previously removed panels.
10.) Run a brief test burn to confirm the unit is operating as it should.