Skip to main content
Product title:

US Stove Vacuum/Pressure Switch: 80549

Product rating:
Product price:
$149.99
Product SKU ! 80549
Product MPN ! 80549
Only 8 Left In Stock
Bullet point features

Frequently Bought Together

Total Price: $176.97

Description

US Stove Company Pellet Stove Vacuum/Pressure Switch.  The vacuum switch is an important safety device that ensures a certain pressure is maintained inside the stove.  This switch is mounted on the rear of the unit and will be connected to a plastic or silicon hose.  If the switch is damaged or not functioning properly it may cause the feed motor to stop turning, an error code to display or not allow the unit to feed fuel during start up.  

Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.



Replacement For Part Numbers:

  • 80549
  • FS6634-1206 (Tridelta)

View Compatible Models

UPC: 012685000855

Compatible Models

    Golden Eagle

  • 5040

    King

  • KP5522
  • Multi-Fuel 8500
  • KP130
  • KP60

    US Stove Company

  • 2400 Window
  • 4840
  • 5040
  • 5500
  • 5500M
  • 5500XL
  • 5501S
  • 5502M
  • 5510
  • 5560
  • 5660
  • 6039T
  • 6041
  • 6041HF
  • 6041I
  • 6041TP
  • 6500
  • 8500
  • KP60-XH
  • US5517-P

Technical Specs

Open Value <.05"WC
Close Value >.05"WC

Instructions

Install Instructions For US Stove Vacuum/Pressure Switch: 80549

To replace the pressure switch:

  1. Unplug the unit
  2. Remove service panel
  3. Remove hose from switch
  4. Remove mounting screws
  5. Install new switch in the same position as the old switch
  6. Connect vacuum hose to gray side of the switch
  7. Connect the wires to either terminal

Troubleshooting

Check the Hose


Before purchasing a new switch or determining that your switch is broken, make sure the hose attached to the switch is not clogged. To check this, remove the hose from the switch and blow through it then reconnect the hose to the gray-side port.


Error Reporting


Flashing Draft Fan Setting - This indicates that the stove is in normal operation and that the vacuum sensor detects a loss of pressure either because the door is open or because there is a negative pressure in the room with respect to the exhaust. If the problem is not remedied and the unit is still in start-up mode you get a ERR-3. If this problem happens during run mode, you will get an ERR-2.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

US Stove Company Pellet Stove Vacuum/Pressure Switch.  The vacuum switch is an important safety device that ensures a certain pressure is maintained inside the stove.  This switch is mounted on the rear of the unit and will be connected to a plastic or silicon hose.  If the switch is damaged or not functioning properly it may cause the feed motor to stop turning, an error code to display or not allow the unit to feed fuel during start up.  

Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.



Replacement For Part Numbers:

  • 80549
  • FS6634-1206 (Tridelta)

View Compatible Models

UPC: 012685000855

Compatible Models

    Golden Eagle

  • 5040

    King

  • KP5522
  • Multi-Fuel 8500
  • KP130
  • KP60

    US Stove Company

  • 2400 Window
  • 4840
  • 5040
  • 5500
  • 5500M
  • 5500XL
  • 5501S
  • 5502M
  • 5510
  • 5560
  • 5660
  • 6039T
  • 6041
  • 6041HF
  • 6041I
  • 6041TP
  • 6500
  • 8500
  • KP60-XH
  • US5517-P

Technical Specs

Open Value <.05"WC
Close Value >.05"WC

Instructions

Install Instructions For US Stove Vacuum/Pressure Switch: 80549

To replace the pressure switch:

  1. Unplug the unit
  2. Remove service panel
  3. Remove hose from switch
  4. Remove mounting screws
  5. Install new switch in the same position as the old switch
  6. Connect vacuum hose to gray side of the switch
  7. Connect the wires to either terminal

Troubleshooting

Check the Hose


Before purchasing a new switch or determining that your switch is broken, make sure the hose attached to the switch is not clogged. To check this, remove the hose from the switch and blow through it then reconnect the hose to the gray-side port.


Error Reporting


Flashing Draft Fan Setting - This indicates that the stove is in normal operation and that the vacuum sensor detects a loss of pressure either because the door is open or because there is a negative pressure in the room with respect to the exhaust. If the problem is not remedied and the unit is still in start-up mode you get a ERR-3. If this problem happens during run mode, you will get an ERR-2.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid