Skip to main content
Skip to main content
Product title:

Austroflamm / Rika Combustion Blower: 102831-AMP

Product rating:
Product price:
$119.99
Product SKU ! 102831-AMP
Product MPN ! 102831
Product availability: In Stock
Bullet point features

Frequently Bought Together

Total Price: $159.97

Description

Combustion Blower for select Austroflamm and Rika stoves. The blower has 4 bolt holes in a square pattern, 4-3/8 inches apart. This part includes the capacitor and Molex plug for the Hall IC sensor.  Gasket sold separately.

Note:  On some units the connector may need to be modified in order to fit. 


Replacement For Part Numbers:

  • 102831
  • 111475
  • ROZ102831

View Compatible Models

Compatible Models

    Austroflamm

  • G1
  • Integra I FS
  • Integra I INS
  • Integra II FS
  • Integra II INS
  • Premio
  • Visio
  • Wega

Technical Specs

Volts 115-120
Cycles 60Hz
Hall IC Sencor White=Encoder | Red=5 volts | Black=ground
Capcitor Start/ Driven (included)

Instructions

Install Instructions For Austroflamm / Rika Combustion Blower: 102831-AMP

If you are replacing a pre-2006 motor, you must cut off the connectors from your old motor and attach them to the corresponding wires from the new motor.

Hall Sensor Wiring:

  • All Austroflamm models except the Wega use the hall sensor. Wega models can use this blower without attaching the 3-wire encoder wires for the sensor.
  • For Rika Integra II, Primo, and Visio models that use the green plug-in blocks on the motherboard for the hall sensor, the white Molex plug can be cut off and the wires can be attached to the green module. left to right the order is: White, Red, Black (White wire is for the encoder, Red is 5 volts, black wire is ground)
  • Note: Sometimes we get these motors where the black encoder ground wire is a blue wire. Treat the blue wire as if it were black.

Motor Wiring:

  • The single blue wire from the motor harness will attach to the stove's terminal block in the same location as the top orange wire from the controller.
  • The double sets of wires (brown/brown) do not connect to anything and need to be wrapped or shielded. Electrical tape around the terminal end will be fine.
  • The (brown/black) will attach to anywhere on the neutral ground section of the terminal block. This section will be the section on the stove's terminal block with more than 1 wire. There should be 4 or 5 connected in this section.

Troubleshooting

If your stove starts and the feed light comes on, but quickly stops feeding pellets, you most likely have a bad Hall Sensor in the blower, and need to replace your combustion blower.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

HOLIDAY UPDATE
Due to the upcoming Christmas and New Years holidays, shippers will not be picking up on the dates below. Additionally, packages may take longer to arrive than expected. We appreciate your understanding and patience during this time.

  • USPS: No pickup on Dec 24th, Dec 25th, and Jan 1st.
  • UPS: No pickup on Dec 24th (except NDA and 2nd Day), Dec 25th, Dec 31st (except NDA and 2nd Day), and Jan 1st.
CANADA UPDATE

Due to the ongoing Canada Post postal workers' strike, we are forced to suspend all ordering to Canada. Please be advised that any shipments that did not clear U.S. customs by November 15th will be delayed until Canada Post is fully operational. We appreciate your understanding and patience during this time.

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

Combustion Blower for select Austroflamm and Rika stoves. The blower has 4 bolt holes in a square pattern, 4-3/8 inches apart. This part includes the capacitor and Molex plug for the Hall IC sensor.  Gasket sold separately.

Note:  On some units the connector may need to be modified in order to fit. 


Replacement For Part Numbers:

  • 102831
  • 111475
  • ROZ102831

View Compatible Models

Technical Specs

Volts 115-120
Cycles 60Hz
Hall IC Sencor White=Encoder | Red=5 volts | Black=ground
Capcitor Start/ Driven (included)

Instructions

Install Instructions For Austroflamm / Rika Combustion Blower: 102831-AMP

If you are replacing a pre-2006 motor, you must cut off the connectors from your old motor and attach them to the corresponding wires from the new motor.

Hall Sensor Wiring:

  • All Austroflamm models except the Wega use the hall sensor. Wega models can use this blower without attaching the 3-wire encoder wires for the sensor.
  • For Rika Integra II, Primo, and Visio models that use the green plug-in blocks on the motherboard for the hall sensor, the white Molex plug can be cut off and the wires can be attached to the green module. left to right the order is: White, Red, Black (White wire is for the encoder, Red is 5 volts, black wire is ground)
  • Note: Sometimes we get these motors where the black encoder ground wire is a blue wire. Treat the blue wire as if it were black.

Motor Wiring:

  • The single blue wire from the motor harness will attach to the stove's terminal block in the same location as the top orange wire from the controller.
  • The double sets of wires (brown/brown) do not connect to anything and need to be wrapped or shielded. Electrical tape around the terminal end will be fine.
  • The (brown/black) will attach to anywhere on the neutral ground section of the terminal block. This section will be the section on the stove's terminal block with more than 1 wire. There should be 4 or 5 connected in this section.

Troubleshooting

If your stove starts and the feed light comes on, but quickly stops feeding pellets, you most likely have a bad Hall Sensor in the blower, and need to replace your combustion blower.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

HOLIDAY UPDATE
Due to the upcoming Christmas and New Years holidays, shippers will not be picking up on the dates below. Additionally, packages may take longer to arrive than expected. We appreciate your understanding and patience during this time.

  • USPS: No pickup on Dec 24th, Dec 25th, and Jan 1st.
  • UPS: No pickup on Dec 24th (except NDA and 2nd Day), Dec 25th, Dec 31st (except NDA and 2nd Day), and Jan 1st.
CANADA UPDATE

Due to the ongoing Canada Post postal workers' strike, we are forced to suspend all ordering to Canada. Please be advised that any shipments that did not clear U.S. customs by November 15th will be delayed until Canada Post is fully operational. We appreciate your understanding and patience during this time.

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 6 reviews
100%
(6)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
R
Robert M.
Quality Part

The installation had a few obstacles due to the age of my Ravelli RV 100 Classic. But it’s back up and running great now. It was good to have the gaskets on-hand to replace while things were apart.

T
Tim R.
Smoke fan

Bought the aftermarket one, works as it should!

A
Anthony C.
Stove fan replacement

It appeared to be an exact replica of the original equipment it went in fine seem to work fine was nice and quiet would buy again

B
Bob T.

Austroflamm/ Rika Integra II Combustion Blower, Part# 102831-AMP

S
Steve W.

Excellent service

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 6 reviews
100%
(6)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
R
Robert M.
Quality Part

The installation had a few obstacles due to the age of my Ravelli RV 100 Classic. But it’s back up and running great now. It was good to have the gaskets on-hand to replace while things were apart.

T
Tim R.
Smoke fan

Bought the aftermarket one, works as it should!

A
Anthony C.
Stove fan replacement

It appeared to be an exact replica of the original equipment it went in fine seem to work fine was nice and quiet would buy again

B
Bob T.

Austroflamm/ Rika Integra II Combustion Blower, Part# 102831-AMP

S
Steve W.

Excellent service

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid