US Stove Furnace Distribution Blower: 80594

Product rating:
Product price:
$299.99
Product SKU ! 80594
Product MPN ! 80594
Product availability: In Stock
Bullet point features

Frequently Bought Together

Total Price: $311.47

Description

USSC (Wood/Coal) Furnace Distribution Blower.  The distribution blower is responsible for circulating room air around the furnace and into your ductwork If the blower is not working as it should, the amount of heat transferred from the furnace into your home may be reduced.  If the fan has been cleaned thoroughly and is not moving the same volume of air as it once did it may need to be replaced.  

Gasket sold separately, part number 89319

 *500 CFM* 


Replacement For Part Numbers:

  • 80594
  • 80874P
  • 80230
  • 80496
  • 80594P
  • US80230
  • 25-41-CD

View Compatible Models

UPC: 012685805948

Compatible Models

    US Stove Company

  • 6100
  • 6220
  • Clayton 1537Q
  • Hot Blast 1300
  • Hot Blast 1357M
  • Hot Blast 1400
  • Hot Blast 1400E
  • Hot Blast 1500
  • Hot Blast 1537G
  • Hot Blast 1537M
  • Hot Blast 1557M
  • Jensen 24A
  • Jensen 30A

Technical Specs

Voltage 120
Amps 1.8
RPM 1590
Hz 60
Depth 8 1/2"
Width 10 1/2"
Height 9 3/4"
Mounting Flange 9 1/2" x 5"
CFM 500

Instructions

Install Instructions For US Stove Furnace Distribution Blower: 80594

1.) Disconnect the power from the unit.

2.) Remove the two screws holding the wire cover to the blower housing.

3.) Remove the wire cover.

4.) Untwist and remove the wire nuts from the wires coming from the blower to the conduit.

5.) Loosen and remove the lock nut holding the conduit to the wire housing (The conduit is now free from the blower).

6.) Next loosen the 4 bolts holding the blower to the furnace.

7.) You can now remove the blower from the unit (Check the gasket at this time. If it is damaged or worn it will need to be replaced).

8.) To install the new blower thread one bolt through the blower and gasket (This will help you position the gasket in place).

9.) Next insert and tighten all four bolts to the rear of the furnace.

10.) Remove the wire cover from the newly installed blower.

11.) Using a flathead screwdriver remove the knockout from the side of the blower housing.

12.) Pull out the wires from the blower wire housing and strip approximately a 1/4" of the plastic off of the ends of the wire.

13.) Insert the wires from the conduit through the knockout and position the conduit in place on the side of the wire housing.

14.) Replace the lock nut on the inside of the wire housing and tighten the nut to secure the conduit to the housing.

15.) Connect the black wire from the blower to the black wire from the conduit and the white wire from the conduit to the white wire from the blower.

16.) Reinstall the wire nuts.

17.) Reposition the cover and tighten the two screws.

18.) Plug in your unit and test the blower.

Troubleshooting

-If your distribution blower does not seem to be moving the same amount of air as it once did inspect and clean the blower. Distribution blowers will often draw dust and pet hair into the blades of the fan when operating.

-If the fan blades become packed with dust, hair, or other debris this can greatly reduce the efficiency of the blower. Often, a thorough cleaning will resolve this issue.

-If the blower continues to rotate at a slower speed after it has been cleaned or you hear excessive noise coming from the fan it may need to be replaced!


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

USSC (Wood/Coal) Furnace Distribution Blower.  The distribution blower is responsible for circulating room air around the furnace and into your ductwork If the blower is not working as it should, the amount of heat transferred from the furnace into your home may be reduced.  If the fan has been cleaned thoroughly and is not moving the same volume of air as it once did it may need to be replaced.  

Gasket sold separately, part number 89319

 *500 CFM* 


Replacement For Part Numbers:

  • 80594
  • 80874P
  • 80230
  • 80496
  • 80594P
  • US80230
  • 25-41-CD

View Compatible Models

UPC: 012685805948

Compatible Models

    US Stove Company

  • 6100
  • 6220
  • Clayton 1537Q
  • Hot Blast 1300
  • Hot Blast 1357M
  • Hot Blast 1400
  • Hot Blast 1400E
  • Hot Blast 1500
  • Hot Blast 1537G
  • Hot Blast 1537M
  • Hot Blast 1557M
  • Jensen 24A
  • Jensen 30A

Technical Specs

Voltage 120
Amps 1.8
RPM 1590
Hz 60
Depth 8 1/2"
Width 10 1/2"
Height 9 3/4"
Mounting Flange 9 1/2" x 5"
CFM 500

Instructions

Install Instructions For US Stove Furnace Distribution Blower: 80594

1.) Disconnect the power from the unit.

2.) Remove the two screws holding the wire cover to the blower housing.

3.) Remove the wire cover.

4.) Untwist and remove the wire nuts from the wires coming from the blower to the conduit.

5.) Loosen and remove the lock nut holding the conduit to the wire housing (The conduit is now free from the blower).

6.) Next loosen the 4 bolts holding the blower to the furnace.

7.) You can now remove the blower from the unit (Check the gasket at this time. If it is damaged or worn it will need to be replaced).

8.) To install the new blower thread one bolt through the blower and gasket (This will help you position the gasket in place).

9.) Next insert and tighten all four bolts to the rear of the furnace.

10.) Remove the wire cover from the newly installed blower.

11.) Using a flathead screwdriver remove the knockout from the side of the blower housing.

12.) Pull out the wires from the blower wire housing and strip approximately a 1/4" of the plastic off of the ends of the wire.

13.) Insert the wires from the conduit through the knockout and position the conduit in place on the side of the wire housing.

14.) Replace the lock nut on the inside of the wire housing and tighten the nut to secure the conduit to the housing.

15.) Connect the black wire from the blower to the black wire from the conduit and the white wire from the conduit to the white wire from the blower.

16.) Reinstall the wire nuts.

17.) Reposition the cover and tighten the two screws.

18.) Plug in your unit and test the blower.

Troubleshooting

-If your distribution blower does not seem to be moving the same amount of air as it once did inspect and clean the blower. Distribution blowers will often draw dust and pet hair into the blades of the fan when operating.

-If the fan blades become packed with dust, hair, or other debris this can greatly reduce the efficiency of the blower. Often, a thorough cleaning will resolve this issue.

-If the blower continues to rotate at a slower speed after it has been cleaned or you hear excessive noise coming from the fan it may need to be replaced!


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
R
Rick K.
Smooth process

Wasn't sure if I could find a blower motor for an older Hot Blast wood stove and ordered this one. Took it out of the box, bolted and wired right up with little effort like the old one. Works great!

W
William B.
Bolted right up

Everything is good. It works and seems to put out more than the old one. Perhaps the old one was not spinning as fast as it should have towards the end. I put this on a US Stove 1500 series Hotblast.

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
R
Rick K.
Smooth process

Wasn't sure if I could find a blower motor for an older Hot Blast wood stove and ordered this one. Took it out of the box, bolted and wired right up with little effort like the old one. Works great!

W
William B.
Bolted right up

Everything is good. It works and seems to put out more than the old one. Perhaps the old one was not spinning as fast as it should have towards the end. I put this on a US Stove 1500 series Hotblast.

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid