Install Instructions For Englander High Density Door Gasket (1/2" x 7'): AC-DGKCPM
Instructional Documents:
An airtight seal around the gaskets is crucial to proper stove performance and safety. The door gasket
should be replaced when it no longer forms a tight seal with the door, or as it becomes frayed, matted or
hard. There are several model doors and gaskets for our units, but all are replaced in basically the
same manner.
Open the stove door and remove the old gasket (NOTE: When replacing glass and/or glass gasket at the
same time, the door gasket should be replaced last). Remove any leftover silicone from the door and/or
from the door channel -you may need to use a scraper to do so.
In most cases it is easiest to remove the door and lay it on a flat working surface. Using t he silicone
provided , put a bead of silicone around the channel on the door . Then, starting in the bottom corner -
furthest away from the handle side - install the new gasket, routing it in the channel and cutting as needed,
being sure to butt the ends to make a complete seal. Reinstall the door and shut and latch it for 24 hours
before use, to allow the silicone to properly set up.