Skip to main content
Skip to main content
Product title:

Heatilator Eco Choice Red Thermister Exhaust Sensing Probe (ESP): 3-20-00844

Product rating:
Product price:
$99.99
Product SKU ! 3-20-00844 (HEA)
Product MPN ! 3-20-00844
Product availability: In Stock
Bullet point features

Description

This version of the ESP is the correct part for any model made after 2008. This updated ESP has red wires, as opposed to the previous probes which could have had black, yellow, or white wires. New Circuit boards are now sensing the condition of the differential pressure switch. (FIG 4) 

Notes for ordering replacement parts:

  • If you need a new probe: Order to match your existing probe. Red= #3-20-00844
  • Black, White, or Yellow Probe: Order the black Probe.
  • If you need a new board: Order using the part numbers included here.
  • If installing on a unit with an old probe = Dipswitch #5 “OFF”.
  • With new probe= Dipswitch #5 “ON”.

This red ESP is used on all models manufactured after 2008 or any model in the list below with an updated controller:


Replacement For Part Number:

  • 3-20-00844

View Compatible Models

UPC: 652174715022

Compatible Models

    Heatilator Eco Choice

  • BA100
  • BH105
  • BH60
  • BIO120

Technical Specs

High Temp Limit 572°F

Videos

Instructions

Install Instructions For Heatilator Eco Choice Red Thermister Exhaust Sensing Probe (ESP): 3-20-00844

You must be careful not to bend an ESP probe if removing it for maintenance purposes. Bending the sheath of the probe will usually ruin the sensor. Likewise, when cleaning your stove, care should be taken to not bend the sensor when cleaning. Do not send brushes or vacuum tools through the stove blindly. Before cleaning your stove for the first time, find the ESP probe and make sure that it is not going to be in the way when cleaning. If it is, remove it from its mount prior to performing work.


Using a 1/4" socket, remove the mounting screw and remove the thermocouple from the stove. Trace the wires back to the control board and unplug the wires.


DIP Setting by Stove Model

Troubleshooting

Harman Product Update: November 18, 2008 PDF Link


  1. If a Red probe is mistakenly used on an old board, the board will read it as an exhaust temperature of around 470° F at room temperature. Therefore, The Combustion and Distribution Blowers will be running immediately.
  2. If a Red probe is used on a new board without dip-switch #5 “ON”, the board will read it as an exhaust temperature of around 470° F at room temperature. Therefore, The Combustion and Distribution Blowers will be running immediately.
  3. If an old probe is used on new board with dip-switch #5 “ON”, the board will read it as an exhaust temperature of 572°F, and will show a “3 blink” status within 30 seconds. The Combustion and Distribution blowers will run as if in an over temperature condition.
  4. If there is insufficient draft, the circuit board will not send power to the feed motor or igniter, and the indicator lights will not be illuminated. However, it will increase the voltage to the combustion blower, in an attempt to improve the draft.
  5. If there is insufficient draft, the Combustion blower will not shut off during shut down, Regardless of ESP temperature. This is especially noticed if a door or hopper lid is left open during shut down.
  6. On the PC45, (3-20-05887), the five hour shut down timer has been eliminated with the use of a red probe.
  7. Make sure the feed motor is properly connected, including the terminal crimps and grounding wire. If not, the software may react as though there is insufficient draft, because the sensing device on the board is receiving a small amount of voltage through the feed motor circuit that should be diverted to ground.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $199!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

This version of the ESP is the correct part for any model made after 2008. This updated ESP has red wires, as opposed to the previous probes which could have had black, yellow, or white wires. New Circuit boards are now sensing the condition of the differential pressure switch. (FIG 4) 

Notes for ordering replacement parts:

  • If you need a new probe: Order to match your existing probe. Red= #3-20-00844
  • Black, White, or Yellow Probe: Order the black Probe.
  • If you need a new board: Order using the part numbers included here.
  • If installing on a unit with an old probe = Dipswitch #5 “OFF”.
  • With new probe= Dipswitch #5 “ON”.

This red ESP is used on all models manufactured after 2008 or any model in the list below with an updated controller:


Replacement For Part Number:

  • 3-20-00844

View Compatible Models

UPC: 652174715022

Technical Specs

High Temp Limit 572°F

Video

Instructions

Assembly Instructions For Heatilator Eco Choice Red Thermister Exhaust Sensing Probe (ESP): 3-20-00844

You must be careful not to bend an ESP probe if removing it for maintenance purposes. Bending the sheath of the probe will usually ruin the sensor. Likewise, when cleaning your stove, care should be taken to not bend the sensor when cleaning. Do not send brushes or vacuum tools through the stove blindly. Before cleaning your stove for the first time, find the ESP probe and make sure that it is not going to be in the way when cleaning. If it is, remove it from its mount prior to performing work.


Using a 1/4" socket, remove the mounting screw and remove the thermocouple from the stove. Trace the wires back to the control board and unplug the wires.


DIP Setting by Stove Model

Troubleshooting

Harman Product Update: November 18, 2008 PDF Link


  1. If a Red probe is mistakenly used on an old board, the board will read it as an exhaust temperature of around 470° F at room temperature. Therefore, The Combustion and Distribution Blowers will be running immediately.
  2. If a Red probe is used on a new board without dip-switch #5 “ON”, the board will read it as an exhaust temperature of around 470° F at room temperature. Therefore, The Combustion and Distribution Blowers will be running immediately.
  3. If an old probe is used on new board with dip-switch #5 “ON”, the board will read it as an exhaust temperature of 572°F, and will show a “3 blink” status within 30 seconds. The Combustion and Distribution blowers will run as if in an over temperature condition.
  4. If there is insufficient draft, the circuit board will not send power to the feed motor or igniter, and the indicator lights will not be illuminated. However, it will increase the voltage to the combustion blower, in an attempt to improve the draft.
  5. If there is insufficient draft, the Combustion blower will not shut off during shut down, Regardless of ESP temperature. This is especially noticed if a door or hopper lid is left open during shut down.
  6. On the PC45, (3-20-05887), the five hour shut down timer has been eliminated with the use of a red probe.
  7. Make sure the feed motor is properly connected, including the terminal crimps and grounding wire. If not, the software may react as though there is insufficient draft, because the sensing device on the board is receiving a small amount of voltage through the feed motor circuit that should be diverted to ground.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $199!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)