Bullet point features

Description

Universal quick drop out thermocouple. Comes with adapter fittings and nuts to adapt to most pilot assemblies. See instructions for applications.

For Honeywell Q334, 1000 Series, C7026, C7034:

Insert thermocouple until it stops and secure with adapter 4.


For Honeywell Q303, Q305, Q308, Q314, Q334A, 2000 Series, Q349, Q359, Q385:

Assemble adapter 5 in lowest groove and pinch with a pair of pliers. Thread nut 7 until it stops. Secure thermocouple using nut 3.


For Honeywell Q308 (old):

Slip nut 3 into position. Thread nut 7 until it stops. Secure thermocouple using nut 3.


For Honeywell Q353:

Add nut 7 to the thermocouple between first and second guide hole in bracket and tighten until the thermocouple stops against first guide hole.


For Junkers BZ1D1Z, BZ2D1Z, CB505:

Insert thermocouple until it stops and secure with adapter 4.


For Junkers CB503:

No adapters needed. Simply insert thermocouple as far as possible.


For Junkers BR55D-Z:

No adapters needed. Secure thermocouple at the end of the thread.


For SIT 10, 16:

No adapters needed. For burners with a distance between flame and bracket of 24 mm: use upper groove and thread for clamping. For burners with a distance between flame and bracket of 30 mm: use lower groove and end of thread for clamping.


For Robertshaw 9B:

Slip bushing 6 over the grooved part of the thermocouple and keep in place with nut 7. Secure thermocouple onto bracket.


For White-Rodgers E33, E35:

Position adapter 5 in the lowest groove as shown and pinch with a pair of pliers. Secure thermocouple using nut 7.


In addition the standard power unit connection nut on the thermocouple, reversible slotted nuts 1,2 and 8 are added to connect the thermocouple to non-Honeywell gas controls.

Jump back to product information tab navigation

Description

Universal quick drop out thermocouple. Comes with adapter fittings and nuts to adapt to most pilot assemblies. See instructions for applications.

For Honeywell Q334, 1000 Series, C7026, C7034:

Insert thermocouple until it stops and secure with adapter 4.


For Honeywell Q303, Q305, Q308, Q314, Q334A, 2000 Series, Q349, Q359, Q385:

Assemble adapter 5 in lowest groove and pinch with a pair of pliers. Thread nut 7 until it stops. Secure thermocouple using nut 3.


For Honeywell Q308 (old):

Slip nut 3 into position. Thread nut 7 until it stops. Secure thermocouple using nut 3.


For Honeywell Q353:

Add nut 7 to the thermocouple between first and second guide hole in bracket and tighten until the thermocouple stops against first guide hole.


For Junkers BZ1D1Z, BZ2D1Z, CB505:

Insert thermocouple until it stops and secure with adapter 4.


For Junkers CB503:

No adapters needed. Simply insert thermocouple as far as possible.


For Junkers BR55D-Z:

No adapters needed. Secure thermocouple at the end of the thread.


For SIT 10, 16:

No adapters needed. For burners with a distance between flame and bracket of 24 mm: use upper groove and thread for clamping. For burners with a distance between flame and bracket of 30 mm: use lower groove and end of thread for clamping.


For Robertshaw 9B:

Slip bushing 6 over the grooved part of the thermocouple and keep in place with nut 7. Secure thermocouple onto bracket.


For White-Rodgers E33, E35:

Position adapter 5 in the lowest groove as shown and pinch with a pair of pliers. Secure thermocouple using nut 7.


In addition the standard power unit connection nut on the thermocouple, reversible slotted nuts 1,2 and 8 are added to connect the thermocouple to non-Honeywell gas controls.

Troubleshooting

  • Tighten nuts 3 and 4 only 1/4 to 1/2 turn beyond finger tight.
  • Tighten nuts for gas control connection with wrench only 1/4 turn beyond finger fight.
  • Do not use thread compound of any kind.
  • Do not bend tubing near fitting after nut has been tightened.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $79 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid
mgctlbxN$MZP mgctlbxV$5.3.2 mgctlbxL$C
Universal Gas Fireplace Thermocouple -- image_01