Install Instructions For US Stove Convection Blower Gasket: 89319
Instructional Notes
1.) Unplug the power from the furnace or turn off the breaker supplying power.
2.) Locate the bolts holding the blower to the rear of the unit.
3.) Loosen the bolts & remove the blower (If the wire supplying power to the motor is not disconnected support the blower during this step).
4.) Hold the new gasket and blower in place and start to thread 1-2 bolts through the blower flange (This will help hold the gasket in place as you reposition the blower).
5.) Position the blower along the rear of the unit and reinstall the previously removed bolts.
6.) Plug in the unit or flip the breaker to restore power.