Product title:

US Stove Distribution Blower (800 CFM): 80600P-AMP [SP4L-153]

Product rating:
Product price:
$249.99

A $100.00 Savings over the OEM

Product SKU ! 80600P-AMP
Product MPN ! 80600P
Product availability: In Stock
Bullet point features

Frequently Bought Together

Total Price: $428.96

Description

USSC (Wood/Coal) Furnace Distribution Blower.  The distribution blower is responsible for circulating room air around the furnace and into your ductwork If the blower is not working as it should, the amount of heat transferred from the furnace into your home may be reduced.  If the fan has been cleaned thoroughly and is not moving the same volume of air as it once did, it may need to be replaced.  

 *800 CFM*


Replacement For Part Numbers:

  • 80600P
  • 80600
  • 80530
  • SP4L-153

View Compatible Models

UPC: 012685806037

Compatible Models

    King

  • Multi-Fuel 8500

    US Stove Company

  • 6500
  • Clayton 1602G
  • Clayton 1602M
  • Clayton 1602R
  • Clayton 1660E

Technical Specs

Volts 115
Cycles 50/60Hz
Amps 2.5/3.0
RPM 1270/1350
CFM 800

Instructions

Install Instructions For US Stove Distribution Blower (800 CFM): 80600P-AMP [SP4L-153]

1.) Disconnect the power from the unit.

2.) Remove the two screws holding the wire cover to the blower housing.

3.) Remove the wire cover.

4.) Untwist and remove the wire nuts from the wires coming from the blower to the conduit.

5.) Loosen and remove the lock nut holding the conduit to the wire housing (The conduit is now free from the blower).

6.) Next loosen the 4 bolts holding the blower to the furnace.

7.) You can now remove the blower from the unit (Check the gasket at this time. If it is damaged or worn it will need to be replaced).

8.) To install the new blower thread one bolt through the blower and gasket (This will help you position the gasket in place. Inspect the tinnerman clips to ensure they are positioned correctly).

9.) Next insert and tighten all four bolts to the rear of the furnace.

10.) Remove the wire cover from the newly installed blower.

11.) Using a flathead screwdriver remove the knockout from the side of the blower housing.

12.) Pull out the wires from the blower wire housing and strip approximately a 1/4" of the plastic off of the ends of the wire.

13.) Insert the wires from the conduit through the knockout and position the conduit in place on the side of the wire housing.

14.) Replace the lock nut on the inside of the wire housing and tighten the nut to secure the conduit to the housing.

15.) Connect the black wire from the blower to the black wire from the conduit and the white wire from the conduit to the white wire from the blower.

16.) Reinstall the wire nuts.

17.) Reposition the cover and tighten the two screws.

18.) Plug in your unit and test the blower.

Troubleshooting

-If your distribution blower does not seem to be moving the same amount of air as it once did inspect and clean the blower. Distribution blowers will often draw dust and pet hair into the blades of the fan when operating.

-If the fan blades become packed with dust, hair, or other debris this can greatly reduce the efficiency of the blower. Often, a thorough cleaning will resolve this issue.

-If the blower continues to rotate at a slower speed after it has been cleaned or you hear excessive noise coming from the fan it may need to be replaced!


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

HOLIDAY UPDATE
Due to the upcoming Christmas and New Years holidays, shippers will not be picking up on the dates below. Additionally, packages may take longer to arrive than expected. We appreciate your understanding and patience during this time.

  • USPS: No pickup on Dec 24th, Dec 25th, and Jan 1st.
  • UPS: No pickup on Dec 24th (except NDA and 2nd Day), Dec 25th, Dec 31st (except NDA and 2nd Day), and Jan 1st.
CANADA UPDATE

Due to the ongoing Canada Post postal workers' strike, we are forced to suspend all ordering to Canada. Please be advised that any shipments that did not clear U.S. customs by November 15th will be delayed until Canada Post is fully operational. We appreciate your understanding and patience during this time.

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

USSC (Wood/Coal) Furnace Distribution Blower.  The distribution blower is responsible for circulating room air around the furnace and into your ductwork If the blower is not working as it should, the amount of heat transferred from the furnace into your home may be reduced.  If the fan has been cleaned thoroughly and is not moving the same volume of air as it once did, it may need to be replaced.  

 *800 CFM*


Replacement For Part Numbers:

  • 80600P
  • 80600
  • 80530
  • SP4L-153

View Compatible Models

UPC: 012685806037

Technical Specs

Volts 115
Cycles 50/60Hz
Amps 2.5/3.0
RPM 1270/1350
CFM 800

Instructions

Install Instructions For US Stove Distribution Blower (800 CFM): 80600P-AMP [SP4L-153]

1.) Disconnect the power from the unit.

2.) Remove the two screws holding the wire cover to the blower housing.

3.) Remove the wire cover.

4.) Untwist and remove the wire nuts from the wires coming from the blower to the conduit.

5.) Loosen and remove the lock nut holding the conduit to the wire housing (The conduit is now free from the blower).

6.) Next loosen the 4 bolts holding the blower to the furnace.

7.) You can now remove the blower from the unit (Check the gasket at this time. If it is damaged or worn it will need to be replaced).

8.) To install the new blower thread one bolt through the blower and gasket (This will help you position the gasket in place. Inspect the tinnerman clips to ensure they are positioned correctly).

9.) Next insert and tighten all four bolts to the rear of the furnace.

10.) Remove the wire cover from the newly installed blower.

11.) Using a flathead screwdriver remove the knockout from the side of the blower housing.

12.) Pull out the wires from the blower wire housing and strip approximately a 1/4" of the plastic off of the ends of the wire.

13.) Insert the wires from the conduit through the knockout and position the conduit in place on the side of the wire housing.

14.) Replace the lock nut on the inside of the wire housing and tighten the nut to secure the conduit to the housing.

15.) Connect the black wire from the blower to the black wire from the conduit and the white wire from the conduit to the white wire from the blower.

16.) Reinstall the wire nuts.

17.) Reposition the cover and tighten the two screws.

18.) Plug in your unit and test the blower.

Troubleshooting

-If your distribution blower does not seem to be moving the same amount of air as it once did inspect and clean the blower. Distribution blowers will often draw dust and pet hair into the blades of the fan when operating.

-If the fan blades become packed with dust, hair, or other debris this can greatly reduce the efficiency of the blower. Often, a thorough cleaning will resolve this issue.

-If the blower continues to rotate at a slower speed after it has been cleaned or you hear excessive noise coming from the fan it may need to be replaced!


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

HOLIDAY UPDATE
Due to the upcoming Christmas and New Years holidays, shippers will not be picking up on the dates below. Additionally, packages may take longer to arrive than expected. We appreciate your understanding and patience during this time.

  • USPS: No pickup on Dec 24th, Dec 25th, and Jan 1st.
  • UPS: No pickup on Dec 24th (except NDA and 2nd Day), Dec 25th, Dec 31st (except NDA and 2nd Day), and Jan 1st.
CANADA UPDATE

Due to the ongoing Canada Post postal workers' strike, we are forced to suspend all ordering to Canada. Please be advised that any shipments that did not clear U.S. customs by November 15th will be delayed until Canada Post is fully operational. We appreciate your understanding and patience during this time.

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 17 reviews
100%
(17)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
R
Rob H.
Best price on these blowers EVER

Looked for these for years, but at 500.00 each it was too much. These were half and they shipped fast. Cudos!

W
Walter V.
Stove replacement Englander Furnace Blower Motor

Thank you very much for your prompt service. Your replacement part arrived quickly and everything was as ordered. Thank you again for your excellent service.

J
Joseph F.
Happy customer

Works smoothly and quietly.
Was happy to have been able to get the right part.

A
Allison C.

Englander Furnace Blower Motor, BM-1376-AMP

N
N.L.
Replacement Blower Motor

Shipped way faster than expected. Excellent.

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form
Ask a Question
  • Will this blower fit a Vogelzang Horseman 2500?

    I just checked, yes, this is the replacement blower for the Norseman 1500 and 2500.

    1500 furnace has one of these and the 2500 furnace has two of these blowers

  • Hi I need to know what the width and length of the opening where it would connect to my woodchuck woodstove please. I'm unsure if it is comparable with my woodstove to replace the blower.

    This is the correct aftermarket blower that is listed for the Woodchuck 826 Furnace. OEM Part, Click here

Customer Reviews

Based on 17 reviews
100%
(17)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
R
Rob H.
Best price on these blowers EVER

Looked for these for years, but at 500.00 each it was too much. These were half and they shipped fast. Cudos!

W
Walter V.
Stove replacement Englander Furnace Blower Motor

Thank you very much for your prompt service. Your replacement part arrived quickly and everything was as ordered. Thank you again for your excellent service.

J
Joseph F.
Happy customer

Works smoothly and quietly.
Was happy to have been able to get the right part.

A
Allison C.

Englander Furnace Blower Motor, BM-1376-AMP

N
N.L.
Replacement Blower Motor

Shipped way faster than expected. Excellent.

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid