US Pellet Stove OEM Combustion Blower (W/ Housing).  The exhaust blower is responsible for drawing smoke out of the unit and pulling combustion air into the stove.  It is important that the blower functions properly.  If the blower is not running as it should, smoke/flue gas may enter the room.  You may also notice a lazy flame and a poor burn as a result of inadequate combustion air being delivered to the fire.

Note: Does not include gasket 88100.

 


Replacement For Part Numbers:

  • A-E-027
  • 80641

View Compatible Models

Compatible Models

    US Stove Company

  • 5040

Technical Specs

Volts 115
Cycles 50/60Hz
AMPS 0.98
RPM 3000
Wiring Connectors 1 Male & 1 Female Wire Lead

Videos

Instructions

Install Instructions For USSC Pellet Stove OEM Combustion Blower (W/ Housing): 80641

To replace the exhaust blower:


  1. Unplug the unit
  2. Open the service panel
  3. Locate the exhaust blower. If your unit has the original OEM blower, you may have to remove the entire blower assembly if the motor cannot be removed from the hub. This will also involve removing the vent from the end of the assembly. If you have a Breckwell Insert, you will need to remove the entire off-set assembly from the of blower assembly and attach it to the new assembly if you have a hub-less motor.
  4. Disconnect wiring
  5. Replace blower assembly along with any gaskets that were disturbed (included).
  6. Reconnect venting if it was disconnected
  7. Reattach the wiring
  8. NOTE: if the venting was removed, make sure to apply RTV silicone to the venting adapter and secure with a single self tapping screw.

Troubleshooting