'The heating season hasn't started yet but the item arrived BEFORE your expected shipping schedule! Customer service helped answer all my questions I had about the part so I am confident the part will work on my stove once the heating season begins. The price was one half of what I would have paid at my local dealer."-Anonymous
This sensor needs to see a draw of negative pressure (suction) of at least 0.05" WC (water column) to close the electrical contacts. The vacuum hose from this switch connects directly to the rear of the stove's firebox. The controller DOES NOT read any output from this switch and will not throw any specific code if the switch is not working. In all applications where this switch is used, it is connected to the feed circuit to cut power to the auger motor. In stoves that use two auger motors, it is on the upper auger motor circuit. Most of the stoves that utilize this switch will also have a hopper lid switch that can cut power to the auger motor as well so you may need to troubleshoot both switches. This part was used in 2006 and later model pellet stoves.
2006 and later model pellet stoves use 1 ea CU-VS and 1 ea PU-VS. Pre 2006 models use 2 ea PU-VS.
The Vacuum Shut Down Switches (Part # PU-VS and CU-VS) help control various functions of the unit. If an operational error occurs in the unit, a switch will either stop the top (feed) auger or shut the unit off; if the unit turns off an E-1 Code (error code) will appear in the Heat Range and Blower Speed windows of the Control Board. Situations that could cause this include power failure, Combustion Blower failure, improper flue installation, a blocked flue (from rodents, nests, etc.), or “dirty burning” from burning improper fuel.
NOTE: The "door ajar" vacuum switch port must be kept clean, or the top auger will cease to function. Locate the porthole to the right of the burn pot and, with the stove unplugged and cooled down, use a brush or pipe cleaner (not a vacuum) to keep this port clear of ash or other debris (see picture).
Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.
Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers
make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please
be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.
Shipping Information
This Item Qualifies For Free Shipping With
Orders Over $49!
HOLIDAY UPDATE
Due to the upcoming Christmas and New Years holidays, shippers will not be picking up on the dates below. Additionally, packages may take longer to arrive than expected. We appreciate your understanding and patience during this time.
USPS:
No pickup on Dec 24th, Dec 25th, and Jan 1st.
UPS:
No pickup on Dec 24th (except NDA and 2nd Day), Dec 25th, Dec 31st (except NDA and 2nd Day), and Jan 1st.
CANADA UPDATE
Due to the ongoing Canada Post postal workers' strike, we are forced to suspend all ordering to Canada. Please be advised that any shipments that did not clear U.S. customs by November 15th will be delayed until Canada Post is fully operational. We appreciate your understanding and patience during this time.
When Will My Order Ship?
All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.
Do You Offer Express Shipping?
Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.
How Does Free Shipping Work?
Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.
Do You Ship To Canada?
We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.
Do You Ship To Alaska Or Hawaii?
We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.
Do You Ship Outside The US Or Canada?
Unfortunately, at this time we do not offer international shipping other than to Canada.
Shipping Time Estimations
For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.
This sensor needs to see a draw of negative pressure (suction) of at least 0.05" WC (water column) to close the electrical contacts. The vacuum hose from this switch connects directly to the rear of the stove's firebox. The controller DOES NOT read any output from this switch and will not throw any specific code if the switch is not working. In all applications where this switch is used, it is connected to the feed circuit to cut power to the auger motor. In stoves that use two auger motors, it is on the upper auger motor circuit. Most of the stoves that utilize this switch will also have a hopper lid switch that can cut power to the auger motor as well so you may need to troubleshoot both switches. This part was used in 2006 and later model pellet stoves.
2006 and later model pellet stoves use 1 ea CU-VS and 1 ea PU-VS. Pre 2006 models use 2 ea PU-VS.
The Vacuum Shut Down Switches (Part # PU-VS and CU-VS) help control various functions of the unit. If an operational error occurs in the unit, a switch will either stop the top (feed) auger or shut the unit off; if the unit turns off an E-1 Code (error code) will appear in the Heat Range and Blower Speed windows of the Control Board. Situations that could cause this include power failure, Combustion Blower failure, improper flue installation, a blocked flue (from rodents, nests, etc.), or “dirty burning” from burning improper fuel.
NOTE: The "door ajar" vacuum switch port must be kept clean, or the top auger will cease to function. Locate the porthole to the right of the burn pot and, with the stove unplugged and cooled down, use a brush or pipe cleaner (not a vacuum) to keep this port clear of ash or other debris (see picture).
Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.
Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers
make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please
be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.
Shipping Info
This Item Qualifies For Free Shipping With
Orders Over $49!
HOLIDAY UPDATE
Due to the upcoming Christmas and New Years holidays, shippers will not be picking up on the dates below. Additionally, packages may take longer to arrive than expected. We appreciate your understanding and patience during this time.
USPS:
No pickup on Dec 24th, Dec 25th, and Jan 1st.
UPS:
No pickup on Dec 24th (except NDA and 2nd Day), Dec 25th, Dec 31st (except NDA and 2nd Day), and Jan 1st.
CANADA UPDATE
Due to the ongoing Canada Post postal workers' strike, we are forced to suspend all ordering to Canada. Please be advised that any shipments that did not clear U.S. customs by November 15th will be delayed until Canada Post is fully operational. We appreciate your understanding and patience during this time.
When Will My Order Ship?
All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.
Do You Offer Express Shipping?
Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.
How Does Free Shipping Work?
Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.
Do You Ship To Canada?
We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.
Do You Ship To Alaska Or Hawaii?
We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.
Do You Ship Outside The US Or Canada?
Unfortunately, at this time we do not offer international shipping other than to Canada.
Shipping Time Estimations
For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.