Skip to main content
Skip to main content
Product title:

Quadra-Fire Mt Vernon Stove Convection Blower (Pre AE): SRV7000-108-AMP

Product rating:
Product price:
$129.99

A $170.00 Savings over the OEM

Product SKU ! SRV7000-108-AMP
Product MPN ! SRV7000-108
Product availability: In Stock
Bullet point features

Frequently Bought Together

Total Price: $164.97

Description

This pellet stove replacement Convection Bower for the Mt Vernon, which is the original model made between 2002-06 (Pre AE). The original part number for this blower was SRV7000-758 and is no longer available.

This blower is also used on the Quadra-Fire CAB50.

The convection blower for the Mt Vernon AE is part SRV7000-260

The convection blower for the Mt Vernon E2/ Trekker is part SRV7080-105


Replacement For Part Numbers:

  • SRV7000-108
  • SRV7000-758

View Compatible Models

UPC: 652174513284

Compatible Models

    Quadra-Fire

  • CAB50-C
  • Mt Vernon

Technical Specs

Volts 115/120
Cycles 60 Hz
Amps 1
RPM 3000
CFM 220
Wiring Connectors 1/4" Male Spades

Instructions

Install Instructions For Quadra-Fire Mt Vernon Stove Convection Blower (Pre AE): SRV7000-108-AMP

Convection Blower Replacement - The convection blower is mounted at the bottom rear of the appliance. There are 2 impellers, one on each side of the motor. The convection blower pushes heated air through the heat exchange system into the room. 

  1. Allow appliance to completely cool down before unplugging the appliance.
  2. The convection blower is located at the bottom rear of the stove. If an outside air kit is also installed, you will first need to remove the outside air flange by removing the 2 screws using a Phillips head screwdriver. You do not need to remove the flex pipe from the flange.
  3. Remove the left side curtain by removing the 3 screws securing the panel to the unit. The 3 screws are located on the side of the stove.
  4. Disconnect the wires from the blower. The wires coming from the wiring harness are purple and white and the wires coming from the blower are black and white.
  5. The blower housing is attached to the firebox with 4 screws, 2 on each side. Loosen the screws on one side and completely remove the screws on the other side. The screw holes are slots and you can now pull the housing away from the unit.

Troubleshooting

If your blower is not getting power, check Snap Disc #1. It is located on the right side of the appliance on the top of the heat exchanger box. There are 2 purple wires connected to it. This snap disc turns the convection blower on and off as needed. Power is always present at snap disc #1. If this switch is stuck in the open position the blower will not power up. If the switch is stuck in a closed position, the blower will not turn off.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

HOLIDAY UPDATE
Due to the upcoming Christmas and New Years holidays, shippers will not be picking up on the dates below. Additionally, packages may take longer to arrive than expected. We appreciate your understanding and patience during this time.

  • USPS: No pickup on Dec 24th, Dec 25th, and Jan 1st.
  • UPS: No pickup on Dec 24th (except NDA and 2nd Day), Dec 25th, Dec 31st (except NDA and 2nd Day), and Jan 1st.
CANADA UPDATE

Due to the ongoing Canada Post postal workers' strike, we are forced to suspend all ordering to Canada. Please be advised that any shipments that did not clear U.S. customs by November 15th will be delayed until Canada Post is fully operational. We appreciate your understanding and patience during this time.

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

This pellet stove replacement Convection Bower for the Mt Vernon, which is the original model made between 2002-06 (Pre AE). The original part number for this blower was SRV7000-758 and is no longer available.

This blower is also used on the Quadra-Fire CAB50.

The convection blower for the Mt Vernon AE is part SRV7000-260

The convection blower for the Mt Vernon E2/ Trekker is part SRV7080-105


Replacement For Part Numbers:

  • SRV7000-108
  • SRV7000-758

View Compatible Models

UPC: 652174513284

Technical Specs

Volts 115/120
Cycles 60 Hz
Amps 1
RPM 3000
CFM 220
Wiring Connectors 1/4" Male Spades

Instructions

Install Instructions For Quadra-Fire Mt Vernon Stove Convection Blower (Pre AE): SRV7000-108-AMP

Convection Blower Replacement - The convection blower is mounted at the bottom rear of the appliance. There are 2 impellers, one on each side of the motor. The convection blower pushes heated air through the heat exchange system into the room. 

  1. Allow appliance to completely cool down before unplugging the appliance.
  2. The convection blower is located at the bottom rear of the stove. If an outside air kit is also installed, you will first need to remove the outside air flange by removing the 2 screws using a Phillips head screwdriver. You do not need to remove the flex pipe from the flange.
  3. Remove the left side curtain by removing the 3 screws securing the panel to the unit. The 3 screws are located on the side of the stove.
  4. Disconnect the wires from the blower. The wires coming from the wiring harness are purple and white and the wires coming from the blower are black and white.
  5. The blower housing is attached to the firebox with 4 screws, 2 on each side. Loosen the screws on one side and completely remove the screws on the other side. The screw holes are slots and you can now pull the housing away from the unit.

Troubleshooting

If your blower is not getting power, check Snap Disc #1. It is located on the right side of the appliance on the top of the heat exchanger box. There are 2 purple wires connected to it. This snap disc turns the convection blower on and off as needed. Power is always present at snap disc #1. If this switch is stuck in the open position the blower will not power up. If the switch is stuck in a closed position, the blower will not turn off.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

HOLIDAY UPDATE
Due to the upcoming Christmas and New Years holidays, shippers will not be picking up on the dates below. Additionally, packages may take longer to arrive than expected. We appreciate your understanding and patience during this time.

  • USPS: No pickup on Dec 24th, Dec 25th, and Jan 1st.
  • UPS: No pickup on Dec 24th (except NDA and 2nd Day), Dec 25th, Dec 31st (except NDA and 2nd Day), and Jan 1st.
CANADA UPDATE

Due to the ongoing Canada Post postal workers' strike, we are forced to suspend all ordering to Canada. Please be advised that any shipments that did not clear U.S. customs by November 15th will be delayed until Canada Post is fully operational. We appreciate your understanding and patience during this time.

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 24 reviews
96%
(23)
4%
(1)
0%
(0)
0%
(0)
0%
(0)
V
Veronica N.
Great service

Came right on time exactly what I ordered. Simple and easy

J
Jazon M.

Easy ordering and fast shipping.

C
Chris C.
Great service

Needed a blower unit asap for my pellet stove. They shipped same day and I got up and running fast. Thank you!!

M
Mark K.
blower fan for MT Vernon stove

fits wells haven't need to run it yet.

J
John N.

Was simple just unplugged the old and slid the new one in

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 24 reviews
96%
(23)
4%
(1)
0%
(0)
0%
(0)
0%
(0)
V
Veronica N.
Great service

Came right on time exactly what I ordered. Simple and easy

J
Jazon M.

Easy ordering and fast shipping.

C
Chris C.
Great service

Needed a blower unit asap for my pellet stove. They shipped same day and I got up and running fast. Thank you!!

M
Mark K.
blower fan for MT Vernon stove

fits wells haven't need to run it yet.

J
John N.

Was simple just unplugged the old and slid the new one in

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid