Skip to main content
Skip to main content
Product title:

Whitfield & Lennox Pressure Switch: 16050001

Product rating:
Product price:
$99.99
Product SKU ! 16050001
Product MPN ! 16050001
Product availability: In Stock
Bullet point features

Frequently Bought Together

Total Price: $179.97

Description

Replacement pressure switch for select Whitfield pellet stoves. This pressure switch exhibits a normally closed circuit, opening when there is back pressure within the stove, such as a clogged vent.


Replacement For Part Number:

  • 16050001

View Compatible Models

Compatible Models

    Whitfield

  • Advantage II-T C
  • Advantage II-T
  • Advantage III
  • Advantage Plus FS
  • Advantage Plus INS
  • Optima 2 FS
  • Optima 3 FS
  • Optima 3 INS
  • Profile 20 FS (7495 - 7494)
  • Profile 30 FS (11905 - 11904)
  • Profile 30 INS (11905 - 11904)
  • Quest Plus INS WP4
  • Traditions T300P

Technical Specs

Water Column .17

Videos

Instructions

Install Instructions For Whitfield & Lennox Pressure Switch: 16050001

Locate the switch on the side of the stove where the combustion/ exhaust fan assembly is located. The switch can be removed by disconnecting the hose, the two wires and removing the two screws that connect to the mounting bracket. Install your new switch and then reconnect the wires and hose. It does not matter which wire goes on to which terminal.

Troubleshooting

This is a pressure switch and NOT a vacuum switch. Most pellet stoves use a vacuum switch to look for negative pressure (vacuum) to close the contacts. A vacuum switch is commonly wired as a normally open (NO) circuit that closes when low pressure (event) meets a certain threshold. This is a pressure switch and it works opposite of a vacuum switch. This switch is normally closed (NC) and power flows through the circuit without a qualifying event. If the vent is clogged, the back pressure will build in the exhaust path and push the diaphragm in the switch to open the circuit (no flow of current). If you suspect that your switch is malfunctioning and you are not getting power through the switch, simply remove the hose from the switch and power should be restored. If this happens, the switch is okay but you have a clogged vent.


The problem with pressure switches in a pellet stoves that are wired NC is that if they fail, they fail in a NC position and if an event happens where the switch should be in the open position, it may not register the unsafe qualifying event and you end up smoking out your house. Because of this, it's always a good idea to test the switch once a year by capping off your vent and try to start the stove.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $199!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

Replacement pressure switch for select Whitfield pellet stoves. This pressure switch exhibits a normally closed circuit, opening when there is back pressure within the stove, such as a clogged vent.


Replacement For Part Number:

  • 16050001

View Compatible Models

Compatible Models

    Whitfield

  • Advantage II-T C
  • Advantage II-T
  • Advantage III
  • Advantage Plus FS
  • Advantage Plus INS
  • Optima 2 FS
  • Optima 3 FS
  • Optima 3 INS
  • Profile 20 FS (7495 - 7494)
  • Profile 30 FS (11905 - 11904)
  • Profile 30 INS (11905 - 11904)
  • Quest Plus INS WP4
  • Traditions T300P

Technical Specs

Water Column .17

Video

Instructions

Assembly Instructions For Whitfield & Lennox Pressure Switch: 16050001

Locate the switch on the side of the stove where the combustion/ exhaust fan assembly is located. The switch can be removed by disconnecting the hose, the two wires and removing the two screws that connect to the mounting bracket. Install your new switch and then reconnect the wires and hose. It does not matter which wire goes on to which terminal.

Troubleshooting

This is a pressure switch and NOT a vacuum switch. Most pellet stoves use a vacuum switch to look for negative pressure (vacuum) to close the contacts. A vacuum switch is commonly wired as a normally open (NO) circuit that closes when low pressure (event) meets a certain threshold. This is a pressure switch and it works opposite of a vacuum switch. This switch is normally closed (NC) and power flows through the circuit without a qualifying event. If the vent is clogged, the back pressure will build in the exhaust path and push the diaphragm in the switch to open the circuit (no flow of current). If you suspect that your switch is malfunctioning and you are not getting power through the switch, simply remove the hose from the switch and power should be restored. If this happens, the switch is okay but you have a clogged vent.


The problem with pressure switches in a pellet stoves that are wired NC is that if they fail, they fail in a NC position and if an event happens where the switch should be in the open position, it may not register the unsafe qualifying event and you end up smoking out your house. Because of this, it's always a good idea to test the switch once a year by capping off your vent and try to start the stove.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $199!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 5 reviews
60%
(3)
40%
(2)
0%
(0)
0%
(0)
0%
(0)
J
JOHN R.C.
FAQ

Fast And Quick (and the right part.)

A
Alejandro B.
Whitfield Parts

Excellent experience throughout the whole process. Installed the new switch and the stove is working perfectly.

P
Peter S.
Excellent

I am a service tech in the Philadelphia Pa and suburbs area and get parts all the time from here. Fast shipping and always good parts. I have ordered from other online parts houses and have had bad parts delivered. Never a bad part and always the right parts. Makes my business trustworthy and look good, Thank you!!

m
michael m.

Whitfield & Lennox Pressure Switch, 16050001

A
Anonymous
Vacuum switch

Installation was a breeze and the switch works perfectly. I will definitely use Stove parts 4 less for future parts purchases.

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form
Ask a Question
  • does this unit have wires that connect to it

    No. This is the vacuum switch only. There are spade connectors on one side to reattach the wires to.

Customer Reviews

Based on 5 reviews
60%
(3)
40%
(2)
0%
(0)
0%
(0)
0%
(0)
J
JOHN R.C.
FAQ

Fast And Quick (and the right part.)

A
Alejandro B.
Whitfield Parts

Excellent experience throughout the whole process. Installed the new switch and the stove is working perfectly.

P
Peter S.
Excellent

I am a service tech in the Philadelphia Pa and suburbs area and get parts all the time from here. Fast shipping and always good parts. I have ordered from other online parts houses and have had bad parts delivered. Never a bad part and always the right parts. Makes my business trustworthy and look good, Thank you!!

m
michael m.

Whitfield & Lennox Pressure Switch, 16050001

A
Anonymous
Vacuum switch

Installation was a breeze and the switch works perfectly. I will definitely use Stove parts 4 less for future parts purchases.