Skip to main content
Skip to main content
Product title:

Whitfield Optima, Profile & Traditions Photo-eye "Proof of Fire": 14750404

Product rating:
Product price:
$189.99
Product SKU ! 14750404
Product MPN ! 14750404
Only 8 Left In Stock
Bullet point features

Description

When the cell detects light from the fire (fire dominance scheme), a 2.4-volt signal is created by the photocell which closes the solenoid in the photo-eye circuit and returns the 5-volt signal back to the control board for “Proof-of-fire”.




Replacement For Part Number:

  • 14750404

View Compatible Models

Compatible Models

    Earth Stove

  • Traditions T300P

    Whitfield

  • Optima 2 FS
  • Optima 3 FS
  • Optima 3 INS
  • Profile 20 FS (Post: 7495)
  • Profile 30 FS (Post: 11905)
  • Profile 30 INS (Post: 11905 and up)
  • Traditions T300P (Post: 5493)
  • Traditions TP300

Technical Specs

Videos

Instructions

Install Instructions For Whitfield Optima, Profile & Traditions Photo-eye "Proof of Fire": 14750404

Startup Sequence for Lennox Whitfield Control boards with Auto Ignition that use a Photo-Eye for “Proof-of-Fire”


  1. All controllers are equipped with a startup timer fault delay of 14 minutes, 15 seconds. If the photo-eye does not detect flame (Fire Dominance Scheme) within this allotted time, the green fault light will flash and all power to components will be cut.
  2. When the power is turned “ON”, either by pressing the power button or initiated by a thermostat, fuel will feed at a 100% rate (constant feed) for 1 minute, 50 seconds with a feed trim setting of “0”. Feed trim settings range from 1:26 to 2:14, depending upon desired range, +4 to -4 respectively.
  3. Combustion fan starts (startup default medium range). Any change to settings are visible on the indicator but will not take effect until “Proof-of-fire”.
  4. Room blower starts (startup default medium range) Any change to settings are visible on the indicator but will not take effect until “Proof-of-fire”.
  5. The igniter is powered “ON”, line voltage.
  6. At 3 minutes, the control board sends a 5-volt signal to photo-eye. When the cell detects light from the fire (fire dominance scheme), a 2.4-volt signal is created by the photocell which closes the solenoid in the photo-eye circuit and returns the 5-volt signal back to the control board, “Proof-of-fire” achieved.
  7. If “Proof-of-fire” is not achieved at 4 minutes, a 2nd supplemental fuel feed is initiated for 30 seconds. At 6 minutes, if “Proof-of-fire” is not achieved a 3rd supplemental fuel feed is initiated for 30 seconds.
  8. If the Photo-Eye loses sight control for more than 3 minutes, 15 seconds at any time or if the controller is powered off, "SHUTDOWN" is initiated.

Troubleshooting

Whitfield stoves made by Lennox used a photo-eye to detect proof of fire. Of the stoves that use the photo-eye, most will have it located in the hopper, sealed in a box directly over the drop tube at the top of the auger flighting, though many Profile 20 and 30 models had the photo-eye located under the hopper. The photo-eye can have 4 points of failure.


  1. Most common and most overlooked, Molex connector at control board where the two yellow wires connect can develop a poor connection and need to be cleaned to allow the 5v signal from the controller to send and return
  2. For stoves with inside hopper mounting, dust (fines) can get into the cover and obstruct the amber lens OR soot can get under the amber lens
  3. Photocell (eye) pins need to be cleaned - Remove photocell from the solenoid, clean with contact cleaner, reinstall, attach clips from DMM to each wire of the photo-eye set the DMM for continuity and shade the eye from any light, there should be no continuity, expose the photo-eye to direct light (sun, flashlight, etc) the DMM should sound off for continuity. If it doesn’t, replace the photo-eye
  4. Check for a wire obstruction in the mounting box, a bent mounting arm or missing or loose nut inside mounting the photo-eye inside the cover. The photo-eye needs to aim straight down into the feed tube, if it is out of alignment, it may not work properly.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $199!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

When the cell detects light from the fire (fire dominance scheme), a 2.4-volt signal is created by the photocell which closes the solenoid in the photo-eye circuit and returns the 5-volt signal back to the control board for “Proof-of-fire”.




Replacement For Part Number:

  • 14750404

View Compatible Models

Compatible Models

    Earth Stove

  • Traditions T300P

    Whitfield

  • Optima 2 FS
  • Optima 3 FS
  • Optima 3 INS
  • Profile 20 FS (Post: 7495)
  • Profile 30 FS (Post: 11905)
  • Profile 30 INS (Post: 11905 and up)
  • Traditions T300P (Post: 5493)
  • Traditions TP300

Instructions

Assembly Instructions For Whitfield Optima, Profile & Traditions Photo-eye "Proof of Fire": 14750404

Startup Sequence for Lennox Whitfield Control boards with Auto Ignition that use a Photo-Eye for “Proof-of-Fire”


  1. All controllers are equipped with a startup timer fault delay of 14 minutes, 15 seconds. If the photo-eye does not detect flame (Fire Dominance Scheme) within this allotted time, the green fault light will flash and all power to components will be cut.
  2. When the power is turned “ON”, either by pressing the power button or initiated by a thermostat, fuel will feed at a 100% rate (constant feed) for 1 minute, 50 seconds with a feed trim setting of “0”. Feed trim settings range from 1:26 to 2:14, depending upon desired range, +4 to -4 respectively.
  3. Combustion fan starts (startup default medium range). Any change to settings are visible on the indicator but will not take effect until “Proof-of-fire”.
  4. Room blower starts (startup default medium range) Any change to settings are visible on the indicator but will not take effect until “Proof-of-fire”.
  5. The igniter is powered “ON”, line voltage.
  6. At 3 minutes, the control board sends a 5-volt signal to photo-eye. When the cell detects light from the fire (fire dominance scheme), a 2.4-volt signal is created by the photocell which closes the solenoid in the photo-eye circuit and returns the 5-volt signal back to the control board, “Proof-of-fire” achieved.
  7. If “Proof-of-fire” is not achieved at 4 minutes, a 2nd supplemental fuel feed is initiated for 30 seconds. At 6 minutes, if “Proof-of-fire” is not achieved a 3rd supplemental fuel feed is initiated for 30 seconds.
  8. If the Photo-Eye loses sight control for more than 3 minutes, 15 seconds at any time or if the controller is powered off, "SHUTDOWN" is initiated.

Troubleshooting

Whitfield stoves made by Lennox used a photo-eye to detect proof of fire. Of the stoves that use the photo-eye, most will have it located in the hopper, sealed in a box directly over the drop tube at the top of the auger flighting, though many Profile 20 and 30 models had the photo-eye located under the hopper. The photo-eye can have 4 points of failure.


  1. Most common and most overlooked, Molex connector at control board where the two yellow wires connect can develop a poor connection and need to be cleaned to allow the 5v signal from the controller to send and return
  2. For stoves with inside hopper mounting, dust (fines) can get into the cover and obstruct the amber lens OR soot can get under the amber lens
  3. Photocell (eye) pins need to be cleaned - Remove photocell from the solenoid, clean with contact cleaner, reinstall, attach clips from DMM to each wire of the photo-eye set the DMM for continuity and shade the eye from any light, there should be no continuity, expose the photo-eye to direct light (sun, flashlight, etc) the DMM should sound off for continuity. If it doesn’t, replace the photo-eye
  4. Check for a wire obstruction in the mounting box, a bent mounting arm or missing or loose nut inside mounting the photo-eye inside the cover. The photo-eye needs to aim straight down into the feed tube, if it is out of alignment, it may not work properly.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $199!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 3 reviews
100%
(3)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
s
sandra t.
Great experience!

We placed 3 orders and had very positive results in a timely manner.

M
Mark M.
Stove parts

Excellent customer service

A
Anonymous
Fixed our pellet stove

Our pellet stove stopped working properly, not heating and putting smoke out by the gallon. We noticed that the pellets weren't burning properly so after much research, the problem was narrowed down to the photoeye or the exhaust fan. Both items were available from Wood Pellet Stove Parts 4 Less and they shipped promptly. The exhaust fan was the culprit, but we hung onto the photoeye as a 'just in case' scenario. I will definitely keep WPSP4L in my favorites for future ordering!

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form
Ask a Question
  • Does this proof of flame sensor fit the T300P?

    Yes.

  • Where is the photo eye on the Whitifeld profile 30?

    Follow the yellow wires from the controller. There were three different places that they mounted the photo-eye, depending on model year.

Customer Reviews

Based on 3 reviews
100%
(3)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
s
sandra t.
Great experience!

We placed 3 orders and had very positive results in a timely manner.

M
Mark M.
Stove parts

Excellent customer service

A
Anonymous
Fixed our pellet stove

Our pellet stove stopped working properly, not heating and putting smoke out by the gallon. We noticed that the pellets weren't burning properly so after much research, the problem was narrowed down to the photoeye or the exhaust fan. Both items were available from Wood Pellet Stove Parts 4 Less and they shipped promptly. The exhaust fan was the culprit, but we hung onto the photoeye as a 'just in case' scenario. I will definitely keep WPSP4L in my favorites for future ordering!