Quadra-Fire Vacuum Pressure Switch without Hoses: SRV7000-531-AMP (NO HOSE)

Product rating:
Product price:
$34.99

A $63.00 Savings over the OEM

Product SKU ! SRV7000-531-AMP-NH
Product MPN ! SRV7000-531
Product availability: In Stock
Bullet point features

Description

The vacuum switch is located inside the mechanical area of the appliance and will have a black or reddish-orange hose attached. This switch closes the feed circuit when negative pressure above .05" WC is present in the firebox. This pressure switch is a safety device to shut off the feed motor if the exhaust or the heat exchanger system is excessively dirty, the venting is obstructed, or if the firebox door is not fully closed and properly sealed.

This is the newest style switch and replaces all previous vacuum switches.


This pressure switch does not come with a hose. If you need the switch and the hose you want part, SRV240-0450

We also sell the hose and switch together part, SRV7000-531-AMP-WH

Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.



Replacement For Part Numbers:

  • SRV7000-531
  • SRV7000-166
  • 7000-166
  • 812-3430
  • 7000-824
  • 7000-624
  • 812-1990
  • SRV7000-447

View Compatible Models

UPC: 652174579402

Compatible Models

    Quadra-Fire

  • 1000 FS
  • 1100i
  • 800 F/S Nova
  • CAB50-C
  • Castile F/S
  • Castile FS MBK
  • Castile Insert
  • Classic Bay 1200
  • Classic Bay 1200-I
  • Contour
  • Edge 60
  • Mt Vernon AE Insert
  • Mt Vernon AE
  • Mt Vernon E2 FS
  • Mt Vernon E2i
  • Mt Vernon
  • Outfitter I
  • Outfitter II
  • Santa Fe B
  • Santa Fe MBK
  • Santa Fe
  • Santa Fe-C INS
  • Trekker Insert
  • Trekker

Technical Specs

Close Value > .05" WC
Open Value < .05 " WC

Instructions

Troubleshooting

Notes:

  1. The hose connection for the vacuum switch, where it connects to the feed tube can sometimes get clogged with pellet dust. Use a paper clip to clear the blockage.
  2. The pellet hopper must have at least a pound of pellets in the hopper to create a seal around the base of the hopper for the switch to close
  3. Check snap disc #2 and make sure it is not tripped if your stove uses 3 snap discs for safety controls
  4. The combustion/ exhaust blower must be turning to create air flow to close the vacuum switch
  5. If your hopper has a hopper lid sensor, the hopper lid must be closed for the circuit to operate.
  6. Using a jumper wire to bypass the vacuum switch, if the stove operates and everything above has been checked, replace the vacuum switch.
  7. If the stove still does not operate with the vacuum switch bypassed, check all of the other safety switches in the feed circuit inluding testing the motor for proper operation.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

The vacuum switch is located inside the mechanical area of the appliance and will have a black or reddish-orange hose attached. This switch closes the feed circuit when negative pressure above .05" WC is present in the firebox. This pressure switch is a safety device to shut off the feed motor if the exhaust or the heat exchanger system is excessively dirty, the venting is obstructed, or if the firebox door is not fully closed and properly sealed.

This is the newest style switch and replaces all previous vacuum switches.


This pressure switch does not come with a hose. If you need the switch and the hose you want part, SRV240-0450

We also sell the hose and switch together part, SRV7000-531-AMP-WH

Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.



Replacement For Part Numbers:

  • SRV7000-531
  • SRV7000-166
  • 7000-166
  • 812-3430
  • 7000-824
  • 7000-624
  • 812-1990
  • SRV7000-447

View Compatible Models

UPC: 652174579402

Compatible Models

    Quadra-Fire

  • 1000 FS
  • 1100i
  • 800 F/S Nova
  • CAB50-C
  • Castile F/S
  • Castile FS MBK
  • Castile Insert
  • Classic Bay 1200
  • Classic Bay 1200-I
  • Contour
  • Edge 60
  • Mt Vernon AE Insert
  • Mt Vernon AE
  • Mt Vernon E2 FS
  • Mt Vernon E2i
  • Mt Vernon
  • Outfitter I
  • Outfitter II
  • Santa Fe B
  • Santa Fe MBK
  • Santa Fe
  • Santa Fe-C INS
  • Trekker Insert
  • Trekker

Technical Specs

Close Value > .05" WC
Open Value < .05 " WC

Troubleshooting

Notes:

  1. The hose connection for the vacuum switch, where it connects to the feed tube can sometimes get clogged with pellet dust. Use a paper clip to clear the blockage.
  2. The pellet hopper must have at least a pound of pellets in the hopper to create a seal around the base of the hopper for the switch to close
  3. Check snap disc #2 and make sure it is not tripped if your stove uses 3 snap discs for safety controls
  4. The combustion/ exhaust blower must be turning to create air flow to close the vacuum switch
  5. If your hopper has a hopper lid sensor, the hopper lid must be closed for the circuit to operate.
  6. Using a jumper wire to bypass the vacuum switch, if the stove operates and everything above has been checked, replace the vacuum switch.
  7. If the stove still does not operate with the vacuum switch bypassed, check all of the other safety switches in the feed circuit inluding testing the motor for proper operation.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 61 reviews
95%
(58)
5%
(3)
0%
(0)
0%
(0)
0%
(0)
J
Jonathan C.
Pellet stove parts

As always fast shipping, parts fit perfectly, definitely will purchase from again. Thank you

J
Jeffery A.S.

Very fast parts delivery

J
James f.

very fast shipping with all of my orders. it's nice to know I can get the parts I need quickly.

K
Karla H.
PelPro parts came fast

Exact parts for less thank you, cause this stove is DIY fixes, ALOT!

C
Chad A.

Pleasant Hearth Vacuum Switch SRV7000-531-AMP NO HOSE

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form
Ask a Question
  • The switch I have now is the 812-3430 but it has 2 wires connected to it, I don’t see that on this one? Also it says no hose, so I just use the hose I have now, kind of crazy questions I know.

    There are two spade connectors on the black side that you will reconnect the wires that you  took off of your old vacuum switch. If the vacuum hose that you have currently is in good condition, then go ahead and reuse it. There is no need to order the kit with the vacuum hose.

Customer Reviews

Based on 61 reviews
95%
(58)
5%
(3)
0%
(0)
0%
(0)
0%
(0)
J
Jonathan C.
Pellet stove parts

As always fast shipping, parts fit perfectly, definitely will purchase from again. Thank you

J
Jeffery A.S.

Very fast parts delivery

J
James f.

very fast shipping with all of my orders. it's nice to know I can get the parts I need quickly.

K
Karla H.
PelPro parts came fast

Exact parts for less thank you, cause this stove is DIY fixes, ALOT!

C
Chad A.

Pleasant Hearth Vacuum Switch SRV7000-531-AMP NO HOSE

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid