Skip to main content
Skip to main content
Product title:

Quadra-Fire Vacuum Pressure Switch with Hoses: SRV7000-531-OEM

Product rating:
Product price:
$97.99
Product SKU ! SRV7000-531-OEM
Product MPN ! SRV7000-531
Only 4 Left In Stock
Bullet point features

Description

The vacuum switch is located inside the mechanical area of the appliance and will have a black or reddish-orange hose attached. This switch closes the feed circuit when negative pressure above .05" WC is present in the firebox. This pressure switch is a safety device to shut off the feed motor if the exhaust or the heat exchanger system is excessively dirty, the venting is obstructed, or if the firebox door is not fully closed and properly sealed.

This is the newest style switch and replaces all previous vacuum switches.

This pressure switch does not come with a hose. If you need the switch and the hose you want part, SRV240-0450

We also sell the hose and switch together part, SRV7000-531-AMP-WH

Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.



Replacement For Part Numbers:

  • SRV7000-531
  • SRV7000-166
  • 7000-166
  • 812-3430
  • 7000-824
  • 7000-624
  • 812-1990
  • SRV7000-447

View Compatible Models

UPC: 652174579402

Compatible Models

    Quadra-Fire

  • 1000 FS
  • 1100i
  • 800 F/S Nova
  • CAB50-C
  • Castile F/S
  • Castile FS MBK
  • Castile Insert
  • Classic Bay 1200
  • Classic Bay 1200-I
  • Contour
  • Edge 60
  • Mt Vernon AE Insert
  • Mt Vernon AE
  • Mt Vernon E2 FS
  • Mt Vernon E2i
  • Mt Vernon
  • Outfitter I
  • Outfitter II
  • Santa Fe B
  • Santa Fe MBK
  • Santa Fe
  • Santa Fe-C INS
  • Trekker Insert
  • Trekker

Technical Specs

Water Column 0.05"

Instructions

Troubleshooting

  1. The hose connection for the vacuum switch, where it connects to the feed tube can sometimes get clogged with pellet dust. Use a paper clip to clear the blockage.
  2. The pellet hopper must have at least a pound of pellets in the hopper to create a seal around the base of the hopper for the switch to close
  3. Check snap disc #2 and make sure it is not tripped if your stove uses 3 snap discs for safety controls
  4. The combustion/ exhaust blower must be turning to create air flow to close the vacuum switch
  5. If your hopper has a hopper lid sensor, the hopper lid must be closed for the circuit to operate.
  6. Using a jumper wire to bypass the vacuum switch, if the stove operates and everything above has been checked, replace the vacuum switch.
  7. If the stove still does not operate with the vacuum switch bypassed, check all of the other safety switches in the feed circuit inluding testing the motor for proper operation.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

The vacuum switch is located inside the mechanical area of the appliance and will have a black or reddish-orange hose attached. This switch closes the feed circuit when negative pressure above .05" WC is present in the firebox. This pressure switch is a safety device to shut off the feed motor if the exhaust or the heat exchanger system is excessively dirty, the venting is obstructed, or if the firebox door is not fully closed and properly sealed.

This is the newest style switch and replaces all previous vacuum switches.

This pressure switch does not come with a hose. If you need the switch and the hose you want part, SRV240-0450

We also sell the hose and switch together part, SRV7000-531-AMP-WH

Vacuum Switch Visual Note: The manufacturer of all OEM and AMP switches has made a design change. The switch received may appear different, but will work the same.



Replacement For Part Numbers:

  • SRV7000-531
  • SRV7000-166
  • 7000-166
  • 812-3430
  • 7000-824
  • 7000-624
  • 812-1990
  • SRV7000-447

View Compatible Models

UPC: 652174579402

Compatible Models

    Quadra-Fire

  • 1000 FS
  • 1100i
  • 800 F/S Nova
  • CAB50-C
  • Castile F/S
  • Castile FS MBK
  • Castile Insert
  • Classic Bay 1200
  • Classic Bay 1200-I
  • Contour
  • Edge 60
  • Mt Vernon AE Insert
  • Mt Vernon AE
  • Mt Vernon E2 FS
  • Mt Vernon E2i
  • Mt Vernon
  • Outfitter I
  • Outfitter II
  • Santa Fe B
  • Santa Fe MBK
  • Santa Fe
  • Santa Fe-C INS
  • Trekker Insert
  • Trekker

Technical Specs

Water Column 0.05"

Troubleshooting

  1. The hose connection for the vacuum switch, where it connects to the feed tube can sometimes get clogged with pellet dust. Use a paper clip to clear the blockage.
  2. The pellet hopper must have at least a pound of pellets in the hopper to create a seal around the base of the hopper for the switch to close
  3. Check snap disc #2 and make sure it is not tripped if your stove uses 3 snap discs for safety controls
  4. The combustion/ exhaust blower must be turning to create air flow to close the vacuum switch
  5. If your hopper has a hopper lid sensor, the hopper lid must be closed for the circuit to operate.
  6. Using a jumper wire to bypass the vacuum switch, if the stove operates and everything above has been checked, replace the vacuum switch.
  7. If the stove still does not operate with the vacuum switch bypassed, check all of the other safety switches in the feed circuit inluding testing the motor for proper operation.

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $49 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
E
Edwin N.
Review of Quadra fire vacuum switch

Very easy to order. Arrived quickly and in perfect condition

F
Francis M.
prompt service

service was excellent, it was shipped promptly and was the right part which worked properly. I was happy with the service, which is why I ordered again within a week.

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
E
Edwin N.
Review of Quadra fire vacuum switch

Very easy to order. Arrived quickly and in perfect condition

F
Francis M.
prompt service

service was excellent, it was shipped promptly and was the right part which worked properly. I was happy with the service, which is why I ordered again within a week.

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid