Skip to main content
Skip to main content
Product title:

Quadra-Fire Mt Vernon AE & Edge 60 Feed Assembly: SRV7034-004

Product rating:
Product price:
$399.99
Product SKU ! SRV7034-004
Product MPN ! SRV7034-004
Only 4 Left In Stock
Bullet point features

Frequently Bought Together

Description

This is the complete feed motor assembly for the Mt Vernon AE Pellet stove, Mt Vernon AE Insert, and the Edge60 built-in. This assembly has slight variations of the bearing and motor mount.

This assembly will work with all Edge60 and AE models though individual parts of this assembly may not fit with parts from previous assemblies. It is recommended to install the whole assembly as is.

This assembly includes the following parts:

  • Feed Spring Assembly 14.5" - SRV7001-046 - Must be adjusted by installer to a depth of 13"
  • Feed Motor Bracket - SRV7034-143, Replaces older style 7043-143 bracket for 410-0552 bearing.
  • Nylon Bearing - SRV7000-598
  • Feed Motor Gasket - SRV7034-144
  • Optical Switch Assembly - SRV7034-038
  • DC Feed Motor - SRV7000-313
  • 7/8" Collar - 229-0520
  • Phillips Screws - (QTY 4) 8-32 X 3/8, 225-0500

NOTE: The installer MUST verify that the auger spring depth is set to 13" from the motor mount prior to installation. Adjustments may be necessary. Instructions are included. Download Auger Spring Bearing Adjustment Instructions PDF


Replacement For Part Number:

  • SRV7034-004

UPC: 652174604791

Compatible Models

    Quadra-Fire

  • Edge 60
  • Mt Vernon AE Insert
  • Mt Vernon AE

Technical Specs

Auger Spring Depth 13"
RPM Variable RPM (voltage controlled)
Direction Normally CW
Amps 1
Volts 12v DC
Connector 4-PIN Molex (part SRV7034-191)

Videos

Instructions

Install Instructions For Quadra-Fire Mt Vernon AE & Edge 60 Feed Assembly: SRV7034-004

The feed system is accessed on the right side of the unit. There are two hooks the assembly hangs from at the top and there is a single phillips screw that holds the assembly in place located at the bottom of the motor mount. The hollow feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the fire pot.

  • The whole assembly can be removed by disconnecting the power at the molex connection, loosening the phillips head screw under the motor on the motor bracket and, pulling the feed assembly out of the feed tube.
  • The power can be reconnected for testing once the assembly is out of the machine.
  • NOTE*- To test the assembly out of the feed tube, stuff a rag into the top of the feed tube where the assembly was mounted to simulate a closed off top which will allow the pressure/ vacuum switch to close once the stove is powered on.

Troubleshooting

Download the Complete Mt Vernon AE Troubleshooting Guide - 2010 .PDF

The feed motor is powered by 12v DC current. After the stove or insert has started (out of "SS" mode), the feed motor runs constantly. Readings will be between 3v-12v depending upon the fuel table and the demand cycle for heat.

If the feed system was recently removed or a new one was installed prior to feeding problems

  1. Make sure the feed system is mounted correctly.
  2. The top of the motor bracket must be hanging on both of two upper hooks.
  3. The bottom of the feed system needs to be secured with the phillips screw.
  4. The gasket for the feed system must be under the motor mount and between the top of the feed tube.
  5. The depth of the auger spring must be set to a depth of 13" from the bottom of the motor mount when secured to the feed motor.

If you keep getting random error codes for 'AUGER JAMMED' but ONLY after the unit has started and achieved fire.

  1. Check the auger spring set screw is tight. If it is not loose, replace the optical sensor, SRV7034-038.
  2. If your feed auger spring is bent, replace it, part SRV7001-046

If you are getting a MIN FP TEMP Error Code: UNIT IS OUT OF FUEL OR CHECK FOR PROPER FUEL SETTINGS. THIS CODE WOULD DISPLAY ANYTIME THE FIRE GOT UNDER 500 DEGREES DURING ITS NORMAL RUN MODE.

  1. Confirm that your fuel setting is correct for the fuel you are using.
  2. Check the auger spring set screw, make sure it is tight.
  3. Check the collar set screw, make sure it is tight. If it is loose, verify that there is 13" of depth from the motor mount to the end of the spring and then tighten the set screw.
  4. If both of these set screws are tight and there is 13" of depth, remove the feed system from the feed tube, seal the top of the feed tube with a rag and run start-up with the feed system removed.
  5. With the feed system removed try to run the unit so that you can watch the rotation of the feed spring. It should be rotating CW with the spring pointed away from you. If the motor is rotating CCW or starts CW then switches to CCW, with the feed system pulled from the stove, replace the optical sensor, part SRV7034-038.
  6. Remove the vacuum hose from the drop tube and make sure there is no obstruction. If there is anything blocking, or partially blocking the inlet, clear it with some wire from a paper clip.
  7. Verify that you are getting at least 3v of power to the motor across the black and white wires in the harness, if you are, replace the feed motor, SRV7000-313.

Other Items to check when the unit is not feeding:

  1. Check the Door & Hopper sensors 7000-375: *Make sure the door & hopper lid is closed and the icons on the wall control are not displayed.
  2. Check over heat snap disc 230-1290: *This is located on the pellet drop chute. Is it tripped? Reset if needed. This will kill power to the feed system.
  3. Check the vacuum switch SRV7000-531: *Check for an error code or test the vacuum switch.
  4. Replace the optical sensor, SRV7034-038: *Replace this part if all previous checks are good.
  5. Replace the feed motor SRV7000-313: *Replace this part if all previous checks are good.
  6. Check the 10-pin harness for a loose pin or broken wire: *Replace the harness if broken. (SRV7034-191)

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

This is the complete feed motor assembly for the Mt Vernon AE Pellet stove, Mt Vernon AE Insert, and the Edge60 built-in. This assembly has slight variations of the bearing and motor mount.

This assembly will work with all Edge60 and AE models though individual parts of this assembly may not fit with parts from previous assemblies. It is recommended to install the whole assembly as is.

This assembly includes the following parts:

  • Feed Spring Assembly 14.5" - SRV7001-046 - Must be adjusted by installer to a depth of 13"
  • Feed Motor Bracket - SRV7034-143, Replaces older style 7043-143 bracket for 410-0552 bearing.
  • Nylon Bearing - SRV7000-598
  • Feed Motor Gasket - SRV7034-144
  • Optical Switch Assembly - SRV7034-038
  • DC Feed Motor - SRV7000-313
  • 7/8" Collar - 229-0520
  • Phillips Screws - (QTY 4) 8-32 X 3/8, 225-0500

NOTE: The installer MUST verify that the auger spring depth is set to 13" from the motor mount prior to installation. Adjustments may be necessary. Instructions are included. Download Auger Spring Bearing Adjustment Instructions PDF


Replacement For Part Number:

  • SRV7034-004

UPC: 652174604791

Technical Specs

Auger Spring Depth 13"
RPM Variable RPM (voltage controlled)
Direction Normally CW
Amps 1
Volts 12v DC
Connector 4-PIN Molex (part SRV7034-191)

Instructions

Assembly Instructions For Quadra-Fire Mt Vernon AE & Edge 60 Feed Assembly: SRV7034-004

The feed system is accessed on the right side of the unit. There are two hooks the assembly hangs from at the top and there is a single phillips screw that holds the assembly in place located at the bottom of the motor mount. The hollow feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the fire pot.

  • The whole assembly can be removed by disconnecting the power at the molex connection, loosening the phillips head screw under the motor on the motor bracket and, pulling the feed assembly out of the feed tube.
  • The power can be reconnected for testing once the assembly is out of the machine.
  • NOTE*- To test the assembly out of the feed tube, stuff a rag into the top of the feed tube where the assembly was mounted to simulate a closed off top which will allow the pressure/ vacuum switch to close once the stove is powered on.

Troubleshooting

Download the Complete Mt Vernon AE Troubleshooting Guide - 2010 .PDF

The feed motor is powered by 12v DC current. After the stove or insert has started (out of "SS" mode), the feed motor runs constantly. Readings will be between 3v-12v depending upon the fuel table and the demand cycle for heat.

If the feed system was recently removed or a new one was installed prior to feeding problems

  1. Make sure the feed system is mounted correctly.
  2. The top of the motor bracket must be hanging on both of two upper hooks.
  3. The bottom of the feed system needs to be secured with the phillips screw.
  4. The gasket for the feed system must be under the motor mount and between the top of the feed tube.
  5. The depth of the auger spring must be set to a depth of 13" from the bottom of the motor mount when secured to the feed motor.

If you keep getting random error codes for 'AUGER JAMMED' but ONLY after the unit has started and achieved fire.

  1. Check the auger spring set screw is tight. If it is not loose, replace the optical sensor, SRV7034-038.
  2. If your feed auger spring is bent, replace it, part SRV7001-046

If you are getting a MIN FP TEMP Error Code: UNIT IS OUT OF FUEL OR CHECK FOR PROPER FUEL SETTINGS. THIS CODE WOULD DISPLAY ANYTIME THE FIRE GOT UNDER 500 DEGREES DURING ITS NORMAL RUN MODE.

  1. Confirm that your fuel setting is correct for the fuel you are using.
  2. Check the auger spring set screw, make sure it is tight.
  3. Check the collar set screw, make sure it is tight. If it is loose, verify that there is 13" of depth from the motor mount to the end of the spring and then tighten the set screw.
  4. If both of these set screws are tight and there is 13" of depth, remove the feed system from the feed tube, seal the top of the feed tube with a rag and run start-up with the feed system removed.
  5. With the feed system removed try to run the unit so that you can watch the rotation of the feed spring. It should be rotating CW with the spring pointed away from you. If the motor is rotating CCW or starts CW then switches to CCW, with the feed system pulled from the stove, replace the optical sensor, part SRV7034-038.
  6. Remove the vacuum hose from the drop tube and make sure there is no obstruction. If there is anything blocking, or partially blocking the inlet, clear it with some wire from a paper clip.
  7. Verify that you are getting at least 3v of power to the motor across the black and white wires in the harness, if you are, replace the feed motor, SRV7000-313.

Other Items to check when the unit is not feeding:

  1. Check the Door & Hopper sensors 7000-375: *Make sure the door & hopper lid is closed and the icons on the wall control are not displayed.
  2. Check over heat snap disc 230-1290: *This is located on the pellet drop chute. Is it tripped? Reset if needed. This will kill power to the feed system.
  3. Check the vacuum switch SRV7000-531: *Check for an error code or test the vacuum switch.
  4. Replace the optical sensor, SRV7034-038: *Replace this part if all previous checks are good.
  5. Replace the feed motor SRV7000-313: *Replace this part if all previous checks are good.
  6. Check the 10-pin harness for a loose pin or broken wire: *Replace the harness if broken. (SRV7034-191)

Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
r
roger m.
f 1 x Quadra-Fire Mt Vernon AE & Edge 60 Feed Assembly, SRV7034-004

Expensive but it solved the problem . My Pellet stove is working , no errors

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
r
roger m.
f 1 x Quadra-Fire Mt Vernon AE & Edge 60 Feed Assembly, SRV7034-004

Expensive but it solved the problem . My Pellet stove is working , no errors