Skip to main content
Skip to main content
Product title:

Harman Room Temperature Sensor: 3-20-00906-OEM

Product rating:
Product price:
$34.99
Product SKU ! 3-20-00906
Product MPN ! 3-20-00906
Product availability: In Stock
Bullet point features

Frequently Bought Together

Description

This room-temperature sensor is required by all Harman pellet stoves and inserts to use the "Room Temp" or "Automatic" mode setting on older units without a touchscreen.

 A 4 BLINK error code at startup is triggered when the controller doesn't detect this probe. This error usually means the probe is damaged but the error can also happen if the probe has become unplugged.

If your probe is missing or damaged the unit can still be used by selecting the"Stove Temp" or "Constant Burn" setting but you will lose the automatic temperature control.

When this probe is attached and functioning and, if the probe is placed properly, your Harman stove or insert should be able to regulate the desired temperature in the room within 1°F of the setpoint on the dial.

There is a 14-foot extension wire available for this probe if you need to extend the length for better placement of the probe, Part # 3-20-674101



Replacement For Part Number:

  • 3-20-00906

View Compatible Models

UPC: 652174686964

Compatible Models

    Harman

  • Accentra 52i
  • Accentra Cast FS
  • Accentra Insert
  • Advance
  • Invincible Insert
  • Invincible RS
  • P35i
  • P35i-C
  • P38
  • P38+ (Post: 008190059)
  • P43
  • P43-C
  • P61-A
  • P61-C
  • P61A
  • P68
  • P68-C
  • PB105
  • PC45
  • PF100
  • PF120
  • Super Magnum Stoker
  • XXV

    Legacy Stoves

  • Super Magnum Stoker

Technical Specs

Length of wire 5 ft
Standard Type 18-2 braided wire
Connections (2) 1/4" Female Spades

Instructions

Install Instructions For Harman Room Temperature Sensor: 3-20-00906-OEM

Installing a new probe is as easy as unplugging the bad one and plugging in the new one. This probe is designed to be plugged into the jack mount locate don the back of freestanding stoves. Insert units will connect to the blue pigtail wires which are connected to the controller.

Troubleshooting

The probe is designed to measure the air temperature at the end of the wire probe. In "Room Temp"/ "Auto" mode, realtime measurements of the room air temperature allow the unit to oscillate between heating up as demanded or idling down as the set point is achieved. If you have the wire near a heat source, such as too close to the stove or venting or in the direct sunlight, your stove will cool down thinking that the room is warmer than it actually is. Likewise, if the end of this probe is near a cold surface, such as a cement floor or drafty doorway, the stove will product more heat than necessary. An ideal spot for the probe is either directly under the unit near the distribution air fan (measuring incoming room air) or somewhere behind the stove, roughly 18" above the floor, out of direct sunlight and preferably not on a cold exterior wall. It's not uncommon to have to play with the placement of this wire to get the stove calibrated properly as there is no way to manually calibrate the signal of the probe.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

This room-temperature sensor is required by all Harman pellet stoves and inserts to use the "Room Temp" or "Automatic" mode setting on older units without a touchscreen.

 A 4 BLINK error code at startup is triggered when the controller doesn't detect this probe. This error usually means the probe is damaged but the error can also happen if the probe has become unplugged.

If your probe is missing or damaged the unit can still be used by selecting the"Stove Temp" or "Constant Burn" setting but you will lose the automatic temperature control.

When this probe is attached and functioning and, if the probe is placed properly, your Harman stove or insert should be able to regulate the desired temperature in the room within 1°F of the setpoint on the dial.

There is a 14-foot extension wire available for this probe if you need to extend the length for better placement of the probe, Part # 3-20-674101



Replacement For Part Number:

  • 3-20-00906

View Compatible Models

UPC: 652174686964

Compatible Models

    Harman

  • Accentra 52i
  • Accentra Cast FS
  • Accentra Insert
  • Advance
  • Invincible Insert
  • Invincible RS
  • P35i
  • P35i-C
  • P38
  • P38+ (Post: 008190059)
  • P43
  • P43-C
  • P61-A
  • P61-C
  • P61A
  • P68
  • P68-C
  • PB105
  • PC45
  • PF100
  • PF120
  • Super Magnum Stoker
  • XXV

    Legacy Stoves

  • Super Magnum Stoker

Technical Specs

Length of wire 5 ft
Standard Type 18-2 braided wire
Connections (2) 1/4" Female Spades

Instructions

Install Instructions For Harman Room Temperature Sensor: 3-20-00906-OEM

Installing a new probe is as easy as unplugging the bad one and plugging in the new one. This probe is designed to be plugged into the jack mount locate don the back of freestanding stoves. Insert units will connect to the blue pigtail wires which are connected to the controller.

Troubleshooting

The probe is designed to measure the air temperature at the end of the wire probe. In "Room Temp"/ "Auto" mode, realtime measurements of the room air temperature allow the unit to oscillate between heating up as demanded or idling down as the set point is achieved. If you have the wire near a heat source, such as too close to the stove or venting or in the direct sunlight, your stove will cool down thinking that the room is warmer than it actually is. Likewise, if the end of this probe is near a cold surface, such as a cement floor or drafty doorway, the stove will product more heat than necessary. An ideal spot for the probe is either directly under the unit near the distribution air fan (measuring incoming room air) or somewhere behind the stove, roughly 18" above the floor, out of direct sunlight and preferably not on a cold exterior wall. It's not uncommon to have to play with the placement of this wire to get the stove calibrated properly as there is no way to manually calibrate the signal of the probe.


Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping With Orders Over $99!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $99 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 13 reviews
92%
(12)
8%
(1)
0%
(0)
0%
(0)
0%
(0)
R
Ron C.
Harman OEM Parts

Ordering process was easy. Item shipped in a timely manner. Received the right part. They paid attention to detail. I’m back in business.

K
Kera
Room Temp Sensor

Product came in exactly what I ordered in OEM packaging. Shipping was fast. Thank you for providing parts for our home heating appliances.

B
Brian V.

Harman Room Temperature Sensor, 3-20-00906-OEM

J
Jeannine S.
Room Temp

The part is working as expected. The house is nice and warm now.

D
David M.
Room temperature sensor

Came exactly as ordered. Very pleased. Also guide for install if needed

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

Based on 13 reviews
92%
(12)
8%
(1)
0%
(0)
0%
(0)
0%
(0)
R
Ron C.
Harman OEM Parts

Ordering process was easy. Item shipped in a timely manner. Received the right part. They paid attention to detail. I’m back in business.

K
Kera
Room Temp Sensor

Product came in exactly what I ordered in OEM packaging. Shipping was fast. Thank you for providing parts for our home heating appliances.

B
Brian V.

Harman Room Temperature Sensor, 3-20-00906-OEM

J
Jeannine S.
Room Temp

The part is working as expected. The house is nice and warm now.

D
David M.
Room temperature sensor

Came exactly as ordered. Very pleased. Also guide for install if needed

Liquid error (layout/theme line 255): Could not find asset snippets/iStock-notify-me.liquid