Harman Control Board without Auto-Ignition: 1-00-06142

Product rating:
Product price:
$399.99
Product SKU ! 1-00-06142
Product MPN ! 1-00-06142
Product availability: In Stock
Bullet point features

Frequently Bought Together

Total Price: $569.97

Description

Circuit board for non-ignition P61, Invincible RS, Invincible FS, Invincible Insert, P38+, retrofit P38's that became P38+ and Mag Stoker Coal stove models. All units will use a black ESP probe.

 

  • P38 and P38+ Pellet Stoves use this controller. If you have a P38 with 3 knobs, this is the correct controller
  • P38 retrofits: This is the control board was used to replace the older 2-knob style controllers on the earliest versions of the P38 pellet stoves. Updated units with this controller became the P38+. This upgrade is available for serial 008190059 and greater and is sold as a kit, part 1-00-7738111 which has this controller and all of the other parts you need to change to use this controller
  • If this is being installed in the Invincible RS Pellet stove you will not need to connect the auger timing microswitch (gray wires) to this board. The new board is already programmed to control the function the microswitch located at terminal "J". The microswitch and the wires can be discarded.
  • This controller is NOT compatible with the Invincible T or the Pellet PRO II. Those circuit boards have been discontinued from Harman and are now obsolete.
  • P61 pellet stoves originally did not come with auto-ignition. This controller is used for those stoves. For P61A pellet stoves, use part 1-00-05886


Replacement For Part Numbers:

  • 1-00-06142
  • 3-20-00928
  • 3-20-05378
  • 3-20-05890
  • 3-20-06142

View Compatible Models

UPC: 652174585571

Compatible Models

    Harman

  • Invincible Insert
  • Invincible RS
  • P38 (Post: 008190059)
  • P38+ (Post: 008190059)
  • P61-A
  • Super Magnum Stoker

    Legacy Stoves

  • Super Magnum Stoker

Technical Specs

Videos

Instructions

Troubleshooting

Harman Pellet Stove - What to do if Your Stove Will Not Turn Off

This is a common problem that many Harman pellet stove owners may experience from time to time and it can be very frustrating for the user. The problem presents itself usually one of two different ways; the stove is cold but power won’t turn off or the stove is warm and is continually feeding very slowly and will only shut down if it runs out of pellets.

Scenario 1 - Cold Stove, Won’t Turn Off When Powered ‘OFF’

The stove is cold. The MODE selection dial is set to OFF and combustion/ exhaust blower continues to run. On the control panel, the only lights that are illuminated are POWER and 

COMBUSTION FAN. If you unplug the stove, the loss of power will cause the stove to turn off and if you plug it back in, the stove may remain off but when the MODE dial is turned the problem repeats itself or, in some instances the stove may enter right back into the error. Additionally, when this error occurs, the stove will NOT advance into the STARTUP mode either, pellets will not feed into the burnpot.

So, here’s what wrong; the pressure switch, commonly referred to as the vacuum switch, is not closing. When the MODE dial is turned from the OFF position, first in the order of operations, the combustion fan is powered up, which creates airflow through the stove. The pressure switch in the stove is here for this purpose, to detect this airflow. At startup, once his operation has been established or “proofed”, the controller detects the closed circuit from the pressure switch and moves to the next order of operation, which is fuel feed and igniter ON. If the pressure switch does not close or the controller does not receive the signal of the closed circuit, the stove will continue to run indefinitely. Additionally, the stove will also not shut off when the MODE dial is turned to OFF unless the pressure switch is closed.

Many folks that read the manual and are able to understand this concept are quick to think that the pressure switch is bad but that is rarely the case. In the hundred or so times I have encountered this problem, maybe once or twice has it actually been a faulty pressure switch so here’s what to look for.

  1. Fan Obstruction - The most common problem is an obstructed combustion fan. Inspect the blower. Verify that it is spinning. If not, there may be a pellet caught in the cooling fan on the backside of it or something like a bird caught in the front side of it preventing it from turning.
  2. Vent Obstruction - The second most common problem is a vent that is obstructed. If there is a bird’s nest in the vent, a dead squirrel, bee’s nest or if the vent is just plain dirty, the combustion fan may not be able to move any air out of the stove and therefore, the pressure switch will not detect any airflow. This is very common with inserts. Ash will fall down the flue and deposit itself at the base of the blower and the blower may not have enough power to get itself spinning.
  3. Air Leak - When the stove is running, the entire inside of the stove is under vacuum pressure as the combustion blower sucks air from the stove and sends it out the vent. IF the hopper lid isn’t sealing, if the fines collection box’s cover isn't secured properly or if the door of the stove isn’t fully closed and latched, or perhaps a gasket for the door or hopper lid is compromised, the pressure switch will not close.
  4. Not Enough Pressure - With some pellet stove models, if the combustion fan cover or ash pan are not installed in the stove, the stove will not be able to create enough pressure to close the switch. I forget which models these are but it is a real thing.
  5. Broken Hopper Lid Switch - Not all pellet stove models from Harman will have a hopper lid switch but if yours does have one, it is wired in series with the pressure switch. The lid switch needs to close in order for the pressure switch to get power. You can troubleshoot this by locating the pressure switch and disconnecting the red and black wires (these wires lead into a gray coated sleeve that runs up to the hopper) that bridge the connection between the white wire and the pressure switch. If this solves the problem, replace the hopper lid switch.

Scenario 2 - The Stove Will Not Shutdown and Continues to Run until the Hopper is Empty

Harman Pellet Stoves are somewhat unique in their feed system design, unlike most pellet stoves that used a gravity feed system, in a Harman stove, the fuel is fed horizontally toward the fire and the coals actually sit behind a slight incline, which allows the fire to burn naturally from the top down. While this approach has many advantages with regards to efficiency and combustion flow, to prevent the fire from burning backward in the stove, the fuel must always be advancing forward, and this is true even during the shutdown process. To achieve shutdown, to get the fire to extinguish itself out, the fuel feed is slowed to 10% and very slowly the air overpowers the fire. When the exhaust sensing probe (ESP) in the stove senses a fall in exhaust temperature below 95°F, the controller cuts power to the stove and the stove will remain ‘OFF’ until a call for heat is initiated again. If the stove continues to run until the hopper is empty, here’s what to look for.

  1. Make Sure You Give it Enough Time - Sometimes we all just become too impatient. Harman Pellet Stoves can run upwards of an hour in shutdown mode, make sure you give the stove enough time to turn off and likewise, make sure there is enough fuel in the hopper to sustain a proper shutdown. There’s no harm in running out of pellets but if your waiting and watching for it to shutdown normally you will need enough fuel to make that happen.
  2. Very Dirty Stove and/or Dirty ESP Sensor - Harman Pellet Stoves can seemingly run forever without much maintenance and while this may seem like a benefit of owning one, the result of too much neglect will be shutdown errors. Clean the stove and venting very well and the problem may remedy itself.
  3. Improper Wiring - Did you or anyone else recently perform work on the stove like replacing a component? If so, there’s a chance that the wires in the back were not connected properly. Harman, unlike most stove makers, uses dedicated “home runs” for their common wires. For each component there is a corresponding colored wired to feed the power and each component has its own white common wire returning to the controller...except for the igniter and the auger motor. They share one common from the pressure switch. VERIFY THAT EACH WHITE WIRE IS CONNECTED TO THE CORRECT COMPONENT BY REFERENCING YOUR PARTICULAR STOVE MODEL. A wiring diagram for your stove is included in your owner's manual and should also be attached somewhere on the stove itself behind the mechanical panel.



Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Information

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information
Jump back to product information tab navigation

Description

Circuit board for non-ignition P61, Invincible RS, Invincible FS, Invincible Insert, P38+, retrofit P38's that became P38+ and Mag Stoker Coal stove models. All units will use a black ESP probe.

 

  • P38 and P38+ Pellet Stoves use this controller. If you have a P38 with 3 knobs, this is the correct controller
  • P38 retrofits: This is the control board was used to replace the older 2-knob style controllers on the earliest versions of the P38 pellet stoves. Updated units with this controller became the P38+. This upgrade is available for serial 008190059 and greater and is sold as a kit, part 1-00-7738111 which has this controller and all of the other parts you need to change to use this controller
  • If this is being installed in the Invincible RS Pellet stove you will not need to connect the auger timing microswitch (gray wires) to this board. The new board is already programmed to control the function the microswitch located at terminal "J". The microswitch and the wires can be discarded.
  • This controller is NOT compatible with the Invincible T or the Pellet PRO II. Those circuit boards have been discontinued from Harman and are now obsolete.
  • P61 pellet stoves originally did not come with auto-ignition. This controller is used for those stoves. For P61A pellet stoves, use part 1-00-05886


Replacement For Part Numbers:

  • 1-00-06142
  • 3-20-00928
  • 3-20-05378
  • 3-20-05890
  • 3-20-06142

View Compatible Models

UPC: 652174585571

Compatible Models

    Harman

  • Invincible Insert
  • Invincible RS
  • P38 (Post: 008190059)
  • P38+ (Post: 008190059)
  • P61-A
  • Super Magnum Stoker

    Legacy Stoves

  • Super Magnum Stoker

Troubleshooting

Harman Pellet Stove - What to do if Your Stove Will Not Turn Off

This is a common problem that many Harman pellet stove owners may experience from time to time and it can be very frustrating for the user. The problem presents itself usually one of two different ways; the stove is cold but power won’t turn off or the stove is warm and is continually feeding very slowly and will only shut down if it runs out of pellets.

Scenario 1 - Cold Stove, Won’t Turn Off When Powered ‘OFF’

The stove is cold. The MODE selection dial is set to OFF and combustion/ exhaust blower continues to run. On the control panel, the only lights that are illuminated are POWER and 

COMBUSTION FAN. If you unplug the stove, the loss of power will cause the stove to turn off and if you plug it back in, the stove may remain off but when the MODE dial is turned the problem repeats itself or, in some instances the stove may enter right back into the error. Additionally, when this error occurs, the stove will NOT advance into the STARTUP mode either, pellets will not feed into the burnpot.

So, here’s what wrong; the pressure switch, commonly referred to as the vacuum switch, is not closing. When the MODE dial is turned from the OFF position, first in the order of operations, the combustion fan is powered up, which creates airflow through the stove. The pressure switch in the stove is here for this purpose, to detect this airflow. At startup, once his operation has been established or “proofed”, the controller detects the closed circuit from the pressure switch and moves to the next order of operation, which is fuel feed and igniter ON. If the pressure switch does not close or the controller does not receive the signal of the closed circuit, the stove will continue to run indefinitely. Additionally, the stove will also not shut off when the MODE dial is turned to OFF unless the pressure switch is closed.

Many folks that read the manual and are able to understand this concept are quick to think that the pressure switch is bad but that is rarely the case. In the hundred or so times I have encountered this problem, maybe once or twice has it actually been a faulty pressure switch so here’s what to look for.

  1. Fan Obstruction - The most common problem is an obstructed combustion fan. Inspect the blower. Verify that it is spinning. If not, there may be a pellet caught in the cooling fan on the backside of it or something like a bird caught in the front side of it preventing it from turning.
  2. Vent Obstruction - The second most common problem is a vent that is obstructed. If there is a bird’s nest in the vent, a dead squirrel, bee’s nest or if the vent is just plain dirty, the combustion fan may not be able to move any air out of the stove and therefore, the pressure switch will not detect any airflow. This is very common with inserts. Ash will fall down the flue and deposit itself at the base of the blower and the blower may not have enough power to get itself spinning.
  3. Air Leak - When the stove is running, the entire inside of the stove is under vacuum pressure as the combustion blower sucks air from the stove and sends it out the vent. IF the hopper lid isn’t sealing, if the fines collection box’s cover isn't secured properly or if the door of the stove isn’t fully closed and latched, or perhaps a gasket for the door or hopper lid is compromised, the pressure switch will not close.
  4. Not Enough Pressure - With some pellet stove models, if the combustion fan cover or ash pan are not installed in the stove, the stove will not be able to create enough pressure to close the switch. I forget which models these are but it is a real thing.
  5. Broken Hopper Lid Switch - Not all pellet stove models from Harman will have a hopper lid switch but if yours does have one, it is wired in series with the pressure switch. The lid switch needs to close in order for the pressure switch to get power. You can troubleshoot this by locating the pressure switch and disconnecting the red and black wires (these wires lead into a gray coated sleeve that runs up to the hopper) that bridge the connection between the white wire and the pressure switch. If this solves the problem, replace the hopper lid switch.

Scenario 2 - The Stove Will Not Shutdown and Continues to Run until the Hopper is Empty

Harman Pellet Stoves are somewhat unique in their feed system design, unlike most pellet stoves that used a gravity feed system, in a Harman stove, the fuel is fed horizontally toward the fire and the coals actually sit behind a slight incline, which allows the fire to burn naturally from the top down. While this approach has many advantages with regards to efficiency and combustion flow, to prevent the fire from burning backward in the stove, the fuel must always be advancing forward, and this is true even during the shutdown process. To achieve shutdown, to get the fire to extinguish itself out, the fuel feed is slowed to 10% and very slowly the air overpowers the fire. When the exhaust sensing probe (ESP) in the stove senses a fall in exhaust temperature below 95°F, the controller cuts power to the stove and the stove will remain ‘OFF’ until a call for heat is initiated again. If the stove continues to run until the hopper is empty, here’s what to look for.

  1. Make Sure You Give it Enough Time - Sometimes we all just become too impatient. Harman Pellet Stoves can run upwards of an hour in shutdown mode, make sure you give the stove enough time to turn off and likewise, make sure there is enough fuel in the hopper to sustain a proper shutdown. There’s no harm in running out of pellets but if your waiting and watching for it to shutdown normally you will need enough fuel to make that happen.
  2. Very Dirty Stove and/or Dirty ESP Sensor - Harman Pellet Stoves can seemingly run forever without much maintenance and while this may seem like a benefit of owning one, the result of too much neglect will be shutdown errors. Clean the stove and venting very well and the problem may remedy itself.
  3. Improper Wiring - Did you or anyone else recently perform work on the stove like replacing a component? If so, there’s a chance that the wires in the back were not connected properly. Harman, unlike most stove makers, uses dedicated “home runs” for their common wires. For each component there is a corresponding colored wired to feed the power and each component has its own white common wire returning to the controller...except for the igniter and the auger motor. They share one common from the pressure switch. VERIFY THAT EACH WHITE WIRE IS CONNECTED TO THE CORRECT COMPONENT BY REFERENCING YOUR PARTICULAR STOVE MODEL. A wiring diagram for your stove is included in your owner's manual and should also be attached somewhere on the stove itself behind the mechanical panel.



Warranty

Unfortunately, sometimes products do not work like they are supposed to. We offer a 90 day warranty on manufacturer defects. Some manufacturers make this a very simple and easy process unfortunately others do not. Items must be used in accordance with the manufacturers guidelines to qualify for warranty replacement. Please be advised that warranty claims for these parts may take up to 4 weeks for processing, and customers must cover shipping.

Shipping Info

This Item Qualifies For Free Shipping!

When Will My Order Ship?

All orders are typically processed within 24 hours of receiving payment and are shipped from us same day if placed before our shipping cutoff time (Monday - Friday: 12PM, Saturday: 10AM, Sunday: No Shipping), orders placed after our cutoff time are shipped the next morning.

Do You Offer Express Shipping?

Yes! Please note the shipping times are based on business days, weekends and holidays do not count to the delivery date. Please see our expedited ship time schedules here.

How Does Free Shipping Work?

Most orders over $199 qualify for free shipping! Orders which ship for free are shipped with either USPS or UPS based on our discretion. If you are using a PO box, free shipping orders will always go USPS.

Do You Ship To Canada?

We ship to Canada! We estimate USPS to take 4-10 days once receiving your package from us. We do not offer expedited shipping of any kind to Canada. Please allow an extra 2-5 days for all shipments to Canada. Free shipping is not available to Canada.

Do You Ship To Alaska Or Hawaii?

We ship to both Alaska and Hawaii! We do not offer next day or two day shipping to Alaska or Hawaii. Free shipping is not available to Alaska or Hawaii.

Do You Ship Outside The US Or Canada?

Unfortunately, at this time we do not offer international shipping other than to Canada.

Shipping Time Estimations

For information on shipping time estimations, see the Shipping Information & Transit Times on the shipping page.

Learn More About Our Shipping Information

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
C
Charles E.B.
Easy replacement

Perfect fit. Excellent quality. Make sure you pay attention to the dipswitch settings and read thoroughly and you'll have no problems

QUESTIONS & ANSWERS

If your question does not concern this specific product, use our contact form
Ask a Question
  • My serial number is WHI-009504/ P38+. Purchased summer 2006. Which control board would I purchase?

    For Harman P38+ pre serial number 008190059 you will need 1-00-7738111  For a replacement control board. This an upgrade kit. Please see the description to see what the kit includes.

  • Can you fix the invincible t control board or what control board will fit ?

    Hi,
    The Invincible T control board has been discontinued, part number 3-20-00600. Harman is not distributing a replacement board for that unit. You may be able to take the board to your local electronics shop and see if it is something that can be repaired or replaced. 

  • I have a P61A WHI-008291- Test date March 1998. The stove still works great but some of the functions are not working. I'm assuming it's the control board since they seem to work in test mode. What control board do I need?

    This is the correct controller for all P61 pellet stoves WITHOUT auto-ignition. The correct controller for P61 stoves WITH auto-ignition is this controller.
    FYI, P61-A, the "A" stands for Auto Ignition. Check your manual, the P61 was the only P Series with a currently supported controller that was available without auto-ignition. The P61-A has a higher serial number than yours, I think.

  • does it come with instructions for dip switch settings

    Yes, it will come with instruction regarding what to have the dip switches set at according to what stove you have.

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
C
Charles E.B.
Easy replacement

Perfect fit. Excellent quality. Make sure you pay attention to the dipswitch settings and read thoroughly and you'll have no problems